Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda HVAC ve Hava İşleme Ekipmanları

Soğuklu Su Dolaşım Pompaları

A base-mounted end-suction centrifugal pump that circulates chilled water between the chiller, air-handling coils and process cooling branches.
  • Stable Hydronic Flow
  • Back-Pull-Out Service
  • Variable-Speed Ready
  • Rigid Base Alignment
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The chilled-water pump couples a single-stage cast-iron volute to a high-efficiency motor on a common baseplate. Its end-suction geometry provides a straight inlet path, while the top discharge fits conventional mechanical-room headers. A guarded flexible coupling accommodates minor alignment tolerance and allows the rotating assembly to be serviced without disturbing connected pipework when a back-pull-out arrangement is selected.

Ana Özellikler

A smoothly contoured volute converts impeller velocity into useful system pressure with limited hydraulic loss.

Common-base motor and pump alignment reduces vibration transmitted to cleanroom piping networks.

Mechanical-seal and coupling access supports planned maintenance without cutting the main suction and discharge lines.

Variable-frequency drive compatibility follows two-way valve demand and reduces unnecessary throttling energy.

Müşteri Ürün Sorunları

Chilled-water service requires correct flow, low vibration and reliable seals across continuously changing cooling demand.

Oversized constant-speed pumps waste energy against throttled valves.A variable-speed motor adjusts differential pressure and flow to actual coil demand.
Poor suction conditions create cavitation noise and impeller damage.A straight end-suction inlet and correctly selected NPSH margin support stable flow into the eye.
Motor-pump misalignment shortens bearing and seal life.A machined common base and guarded flexible coupling preserve shaft alignment.
Seal replacement causes extended system shutdown.Back-pull-out access removes the rotating assembly while the volute remains connected to the piping.

Tipik uygulamalar

Primary chilled-water loopsSecondary variable-flow distributionCleanroom AHU coil circuitsProcess-equipment cooling waterLow-temperature laboratory systems

Teknik parametreler

Typical mechanical construction for a cleanroom chilled-water pump set is summarized below.

Temel malzemelerCast-iron volute with stainless steel or bronze impeller and steel shaft
Panel kalınlığı8-16 mm fabricated steel baseplate thickness
Effective Width (Etkili Genişlik)350-900 mm typical pump-set width
Maksimum uzunlukUp to 2400 mm including motor and coupling
Çelik yüz yüze kalınlığı1.5-2.5 mm removable coupling-guard sheet
Core Density (Çekirdek Yoğunluğu)Approximately 7000-7300 kg/m³ for cast-iron volute material
Termal İletkenlikApproximately 45-55 W/(m·K) for cast-iron wetted casing
Yüzey bitirmeBlue epoxy coating on cast iron with painted steel base
Ortak tipFlanged suction/discharge, flexible shaft coupling and bolted base mounts
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Stainless steel or bronze impellerMechanical-seal material combinationsVariable-frequency drive and differential-pressure sensorSingle duty, duty-standby or twin-pump skid

Planning a Chilled-Water Circulation Pump specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim