商品紹介
The chilled-water pump couples a single-stage cast-iron volute to a high-efficiency motor on a common baseplate. Its end-suction geometry provides a straight inlet path, while the top discharge fits conventional mechanical-room headers. A guarded flexible coupling accommodates minor alignment tolerance and allows the rotating assembly to be serviced without disturbing connected pipework when a back-pull-out arrangement is selected.
主要な特徴
Common-base motor and pump alignment reduces vibration transmitted to cleanroom piping networks.
Mechanical-seal and coupling access supports planned maintenance without cutting the main suction and discharge lines.
Variable-frequency drive compatibility follows two-way valve demand and reduces unnecessary throttling energy.
お客様の製品に関する懸念事項
Chilled-water service requires correct flow, low vibration and reliable seals across continuously changing cooling demand.
Oversized constant-speed pumps waste energy against throttled valves.A variable-speed motor adjusts differential pressure and flow to actual coil demand.
Poor suction conditions create cavitation noise and impeller damage.A straight end-suction inlet and correctly selected NPSH margin support stable flow into the eye.
Motor-pump misalignment shortens bearing and seal life.A machined common base and guarded flexible coupling preserve shaft alignment.
Seal replacement causes extended system shutdown.Back-pull-out access removes the rotating assembly while the volute remains connected to the piping.
典型的な用途
Primary chilled-water loopsSecondary variable-flow distributionCleanroom AHU coil circuitsProcess-equipment cooling waterLow-temperature laboratory systems
技術的なパラメータ
Typical mechanical construction for a cleanroom chilled-water pump set is summarized below.
| コア材料 | Cast-iron volute with stainless steel or bronze impeller and steel shaft |
|---|---|
| パネルの厚さ | 8-16 mm fabricated steel baseplate thickness |
| 有効幅 | 350-900 mm typical pump-set width |
| 最大長さ | Up to 2400 mm including motor and coupling |
| 鋼鉄の厚さを直面する | 1.5-2.5 mm removable coupling-guard sheet |
| コア密度 | Approximately 7000-7300 kg/m³ for cast-iron volute material |
| 熱伝導率 | Approximately 45-55 W/(m·K) for cast-iron wetted casing |
| 表面仕上げ | Blue epoxy coating on cast iron with painted steel base |
| ジョイントタイプ | Flanged suction/discharge, flexible shaft coupling and bolted base mounts |
| カスタマイズ | 意図したアプリケーションと動作環境に基づいて利用できます。 |
利用可能なオプション
Stainless steel or bronze impellerMechanical-seal material combinationsVariable-frequency drive and differential-pressure sensorSingle duty, duty-standby or twin-pump skid
Planning a Chilled-Water Circulation Pump specification?