Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Kontrolü ve Çevre İzleme Sistemleri

Hava akışı kontrol sistemi

A closed-loop airflow package that measures supply or exhaust volume and drives a modulating damper to maintain the commanded cleanroom air quantity.
  • Closed-Loop Air Volume
  • Multi-Point Duct Sensing
  • Fast Damper Actuation
  • Stable Low-Flow Control
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The airflow control system combines a duct averaging sensor, differential pressure transmitter, airflow controller and modulating damper actuator. The controller converts the measured velocity pressure into air volume using the configured duct area and continuously positions the damper. Low-flow cutoffs and sensor filtering prevent noisy readings from driving the actuator unnecessarily. The package can regulate supply, return or exhaust air and can share measured volume with the room pressure controller for coordinated cascade control.

Ana Özellikler

Averaging duct pickup samples multiple points instead of relying on one local velocity.

Configured duct dimensions convert pressure signal into a usable airflow-volume value.

Modulating actuator feedback confirms the commanded damper position was reached.

Filtering, deadband and low-flow handling stabilize control near minimum ventilation rates.

Müşteri Ürün Sorunları

Reliable air-volume control depends on representative sensing and an actuator response matched to the duct and pressure conditions.

A single-point duct reading changes with turbulence and elbow location.A multi-point averaging pickup provides a more representative velocity-pressure signal.
The damper hunts around the minimum airflow setpoint.Appropriate filtering, deadband and low-flow cutoff prevent reaction to measurement noise.
The displayed air volume is wrong after a duct size change.Field-configurable duct area and sensor coefficient recalculate volume for the installed branch.
A disconnected actuator is not noticed until room pressure drifts.Position feedback and airflow deviation alarms identify failed movement before the room leaves its normal band.

Tipik uygulamalar

Cleanroom supply-air branchesProcess exhaust regulationLaboratory make-up airPressure-cascade airflow tracking

Teknik parametreler

Typical construction for a cleanroom duct airflow controller and actuator package is listed below.

Temel malzemelerAluminum averaging probe, flame-retardant polymer controller and galvanized steel damper frame
Panel kalınlığı60-140 mm controller and transmitter depth
Effective Width (Etkili Genişlik)120-300 mm controller width
Maksimum uzunlukAveraging probes up to 2000 mm
Çelik yüz yüze kalınlığı0.8-1.5 mm galvanized steel damper casing
Core Density (Çekirdek Yoğunluğu)2650-2750 kg/m³ for aluminum probe components
Termal İletkenlik150-220 W/(m·K) for the aluminum sensing probe
Yüzey bitirmeNatural anodized aluminum probe with white controller and zinc-coated damper frame
Ortak tipFlanged duct pickup with barbed pressure ports and direct-coupled damper actuator
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Supply or exhaust configurationCircular or rectangular duct probesBACnet or Modbus controllerSpring-return damper actuator

Planning a Airflow Control System specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim