Sistem kawalan aliran udara

A closed-loop airflow package that measures supply or exhaust volume and drives a modulating damper to maintain the commanded cleanroom air quantity.
  • Closed-Loop Air Volume
  • Multi-Point Duct Sensing
  • Fast Damper Actuation
  • Stable Low-Flow Control
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The airflow control system combines a duct averaging sensor, differential pressure transmitter, airflow controller and modulating damper actuator. The controller converts the measured velocity pressure into air volume using the configured duct area and continuously positions the damper. Low-flow cutoffs and sensor filtering prevent noisy readings from driving the actuator unnecessarily. The package can regulate supply, return or exhaust air and can share measured volume with the room pressure controller for coordinated cascade control.

Ciri-ciri Utama

Averaging duct pickup samples multiple points instead of relying on one local velocity.

Configured duct dimensions convert pressure signal into a usable airflow-volume value.

Modulating actuator feedback confirms the commanded damper position was reached.

Filtering, deadband and low-flow handling stabilize control near minimum ventilation rates.

Kebimbangan Produk Pelanggan

Reliable air-volume control depends on representative sensing and an actuator response matched to the duct and pressure conditions.

A single-point duct reading changes with turbulence and elbow location.A multi-point averaging pickup provides a more representative velocity-pressure signal.
The damper hunts around the minimum airflow setpoint.Appropriate filtering, deadband and low-flow cutoff prevent reaction to measurement noise.
The displayed air volume is wrong after a duct size change.Field-configurable duct area and sensor coefficient recalculate volume for the installed branch.
A disconnected actuator is not noticed until room pressure drifts.Position feedback and airflow deviation alarms identify failed movement before the room leaves its normal band.

Permohonan yang biasa

Cleanroom supply-air branchesProcess exhaust regulationLaboratory make-up airPressure-cascade airflow tracking

Parameter teknikal

Typical construction for a cleanroom duct airflow controller and actuator package is listed below.

Bahan TerasAluminum averaging probe, flame-retardant polymer controller and galvanized steel damper frame
Ketebalan Panel60-140 mm controller and transmitter depth
Lebar berkesan120-300 mm controller width
Panjang maksimumAveraging probes up to 2000 mm
Keluli Menghadapi Ketebalan0.8-1.5 mm galvanized steel damper casing
Ketumpatan teras2650-2750 kg/m³ for aluminum probe components
Kekonduksian Terma150-220 W/(m·K) for the aluminum sensing probe
Kemasan permukaanNatural anodized aluminum probe with white controller and zinc-coated damper frame
Jenis BersatuFlanged duct pickup with barbed pressure ports and direct-coupled damper actuator
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Supply or exhaust configurationCircular or rectangular duct probesBACnet or Modbus controllerSpring-return damper actuator