Airflow Control System

A closed-loop airflow package that measures supply or exhaust volume and drives a modulating damper to maintain the commanded cleanroom air quantity.
  • Closed-Loop Air Volume
  • Multi-Point Duct Sensing
  • Fast Damper Actuation
  • Stable Low-Flow Control

Produkteinführung

The airflow control system combines a duct averaging sensor, differential pressure transmitter, airflow controller and modulating damper actuator. The controller converts the measured velocity pressure into air volume using the configured duct area and continuously positions the damper. Low-flow cutoffs and sensor filtering prevent noisy readings from driving the actuator unnecessarily. The package can regulate supply, return or exhaust air and can share measured volume with the room pressure controller for coordinated cascade control.

Key Features

Averaging duct pickup samples multiple points instead of relying on one local velocity.

Configured duct dimensions convert pressure signal into a usable airflow-volume value.

Modulating actuator feedback confirms the commanded damper position was reached.

Filtering, deadband and low-flow handling stabilize control near minimum ventilation rates.

Kunden Produktbedenken

Reliable air-volume control depends on representative sensing and an actuator response matched to the duct and pressure conditions.

A single-point duct reading changes with turbulence and elbow location.A multi-point averaging pickup provides a more representative velocity-pressure signal.
The damper hunts around the minimum airflow setpoint.Appropriate filtering, deadband and low-flow cutoff prevent reaction to measurement noise.
The displayed air volume is wrong after a duct size change.Field-configurable duct area and sensor coefficient recalculate volume for the installed branch.
A disconnected actuator is not noticed until room pressure drifts.Position feedback and airflow deviation alarms identify failed movement before the room leaves its normal band.

Typische Anwendungen

Cleanroom supply-air branchesProcess exhaust regulationLaboratory make-up airPressure-cascade airflow tracking

Technische Parameter

Typical construction for a cleanroom duct airflow controller and actuator package is listed below.

Core MaterialAluminum averaging probe, flame-retardant polymer controller and galvanized steel damper frame
Panel Dicke60-140 mm controller and transmitter depth
Effektive Breite120-300 mm controller width
Maximale LängeAveraging probes up to 2000 mm
Stahl facing Dicke0.8-1.5 mm galvanized steel damper casing
Kerndichte2650-2750 kg/m³ for aluminum probe components
Thermische Leitfähigkeit150-220 W/(m·K) for the aluminum sensing probe
Oberfläche FinishNatural anodized aluminum probe with white controller and zinc-coated damper frame
Gemeinsamer TypFlanged duct pickup with barbed pressure ports and direct-coupled damper actuator
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Supply or exhaust configurationCircular or rectangular duct probesBACnet or Modbus controllerSpring-return damper actuator