Sistema de control de flujo de aire

A closed-loop airflow package that measures supply or exhaust volume and drives a modulating damper to maintain the commanded cleanroom air quantity.
  • Closed-Loop Air Volume
  • Multi-Point Duct Sensing
  • Fast Damper Actuation
  • Stable Low-Flow Control
Solicite un presupuesto. Browse productos

Introducción del producto

The airflow control system combines a duct averaging sensor, differential pressure transmitter, airflow controller and modulating damper actuator. The controller converts the measured velocity pressure into air volume using the configured duct area and continuously positions the damper. Low-flow cutoffs and sensor filtering prevent noisy readings from driving the actuator unnecessarily. The package can regulate supply, return or exhaust air and can share measured volume with the room pressure controller for coordinated cascade control.

Características clave

Averaging duct pickup samples multiple points instead of relying on one local velocity.

Configured duct dimensions convert pressure signal into a usable airflow-volume value.

Modulating actuator feedback confirms the commanded damper position was reached.

Filtering, deadband and low-flow handling stabilize control near minimum ventilation rates.

Preocupaciones del producto del cliente

Reliable air-volume control depends on representative sensing and an actuator response matched to the duct and pressure conditions.

A single-point duct reading changes with turbulence and elbow location.A multi-point averaging pickup provides a more representative velocity-pressure signal.
The damper hunts around the minimum airflow setpoint.Appropriate filtering, deadband and low-flow cutoff prevent reaction to measurement noise.
The displayed air volume is wrong after a duct size change.Field-configurable duct area and sensor coefficient recalculate volume for the installed branch.
A disconnected actuator is not noticed until room pressure drifts.Position feedback and airflow deviation alarms identify failed movement before the room leaves its normal band.

Aplicaciones típicas

Cleanroom supply-air branchesProcess exhaust regulationLaboratorio de maquillaje aire porPressure-cascade airflow tracking

Parámetros técnicos

Typical construction for a cleanroom duct airflow controller and actuator package is listed below.

Materiales CoreAluminum averaging probe, flame-retardant polymer controller and galvanized steel damper frame
Panel de espesor60-140 mm controller and transmitter depth
Ancho efectivo120-300 mm controller width
Longitud máximaAveraging probes up to 2000 mm
Acero frente a espesor0.8-1.5 mm galvanized steel damper casing
Densidad Core2650-2750 kg/m³ for aluminum probe components
Conductividad térmica150-220 W/(m·K) for the aluminum sensing probe
Superficie acabadaNatural anodized aluminum probe with white controller and zinc-coated damper frame
Tipo conjuntoFlanged duct pickup with barbed pressure ports and direct-coupled damper actuator
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Supply or exhaust configurationCircular or rectangular duct probesBACnet or Modbus controllerSpring-return damper actuator