Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Kontrol edilen malzeme transferleri

Pass Boxes & Transfer Hatches

Move materials between cleanroom zones with fewer personnel entries. Explore static, HEPA-filtered, VHP and specialized pass boxes, with chamber sizes, door layouts and transfer arrangements suited to your payload and process.

19pass boxes and transfer chambers
19 Transfer ConfigurationsStatic stainless steel cleanroom pass box on a white background
01Define payload dimensions, weight, packaging and transfer frequency.
02Identify room pressure relationship and the acceptable direction of leakage.
03Confirm whether airflow, particle removal, surface treatment or temperature control is required.
04Provide wall construction, installation height, door arrangement and available utilities.
Selection Matrix

How to Select Pass Boxes & Transfer Hatches

Start with the operating task and site constraints, then compare the product direction that best matches the intended use.

Buyer requirementProduct directionWhy it helps
Simple transfer between compatible clean zonesStatic pass box or transfer hatchPayload size and door interlocking
Filtered chamber without site ductworkSelf-contained HEPA pass boxPower and filter service access
Continuous controlled airflow over payloadDynamic or unidirectional-flow pass boxAirflow direction and room pressures
Remove loose particles from compatible packagesMaterial air-shower pass boxPackaging durability and cycle time
Timed accessible-surface treatmentUV-C material treatment pass boxShadowing and material compatibility
VHP-compatible transfer cycleVHP pass boxCycle interfaces, sealing and aeration
Containment or controlled leakage directionBiosafety, negative- or positive-pressure pass boxSupply/exhaust strategy and service access
Large, refrigerated or special-area transferApplication-specific chamberPayload, temperature and project conditions

Compare 19 Pass Boxes & Transfer Hatches

Narrow your choices by the features that matter to your application. View specifications and add suitable models to your inquiry list for a tailored quote.

19 models shown
Material Air-Shower Pass Box main product view

Malzeme Air-Shower Pass Kutusu

A timed material chamber that uses filtered cleaning jets and return grilles to remove loose particles from compatible packages.

Air showerMaterial cleaningTimed cycle
View Model →
Floor-Standing Cleanroom Pass Box main product view

Temizlik Odası Pass Kutusu

A reinforced, floor-supported cleanroom pass box for transferring larger loads at a practical handling height.

Floor-standingLarge loadsInterlocked
View Model →
Refrigerated Cleanroom Pass Box main product view

Soğutucu Temiz Oda Pass Kutusu

An insulated, temperature-controlled pass box for short transfers of compatible temperature-sensitive materials.

RefrigeratedInsulatedTemperature-sensitive
View Model →
Hazardous-Area Pass Box main product view

Tehlikeli Alan Pass Kutusu

A configurable sealed pass box for controlled transfer at hazardous process boundaries, without assigning a specific area classification.

Hazardous processSealedProject review
View Model →
Cleanroom Transfer Hatch main product view

Temiz Oda Transfer Hatch

A shallow wall-mounted transfer hatch for documents, sealed packs and small components where a full-depth pass box is unnecessary.

Transfer hatchSmall payloadWall-mounted
View Model →
Laboratory Specimen Pass Box main product view

Laboratuvar Örnekleri Pass Box

A compact interlocked chamber with a removable sample tray for controlled transfer of labelled specimens between collection and laboratory areas.

LaboratorySpecimensRemovable tray
View Model →
No models match every selected filter.
Reset one or more filters to compare a broader group.
Solutions for Your Application

Overcome the Challenges in Your Process

A pass box should be selected around the payload, room pressure relationship and required chamber process rather than by external size alone.

An underspecified chamber can create bypass risk, poor loading ergonomics, incompatible treatment or unnecessary transfer delays.Coordinate payload envelope, airflow or treatment method, sealing, interlock logic and service access as one transfer workflow.
The payload fits the opening but cannot be loaded safely at the installed height.Confirm the complete payload envelope, weight and handling method before fixing chamber size, sill height or a floor-standing arrangement.
Door opening disturbs the intended pressure relationship between adjacent rooms.Coordinate door interlocking, chamber leakage direction and any filtered supply or exhaust with the actual room pressure cascade.
A treatment cycle does not reach shadowed surfaces or is incompatible with the transferred packaging.Review payload orientation, exposed surfaces and material compatibility before selecting UV-C, VHP or air-shower treatment.
Filters, lamps or control components cannot be serviced after the pass box is built into the wall.Define service side, removable panels, utility connections and replacement clearances during opening and wall-interface coordination.
Get a Tailored Quote

Tell Us What Your Application Needs

  • Payload dimensions and weight
  • Transfer frequency and direction
  • Adjacent-room pressure relationship
  • Required airflow or treatment process
  • Wall opening and installation height
  • Door number and orientation
  • Available power, ductwork and services
  • Destination and project stage
Common Questions

Before choosing Pass Boxes & Transfer Hatches

A static pass box provides an interlocked transfer chamber without active recirculating airflow. A dynamic model adds filtered airflow to control the chamber environment during transfer.

Pressure control is considered when the transfer boundary must favour payload protection or containment. The adjacent-room pressures and exhaust or supply strategy must be reviewed together.

Yes. Floor-standing and large transfer chambers can be coordinated around the payload envelope, handling height, door arrangement and available structural opening.

No. Treatment selection depends on material compatibility, surface exposure, packaging and the intended process. Those conditions must be confirmed for each project.

Get a Pass Box Matched to Your Transfer Process

Share your payload dimensions, room conditions and transfer frequency. We will help you choose a suitable chamber configuration and quote your requirements.

Request a Pass Box Quote →
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim