Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Transfer Bahan yang Dikendalikan

Pass Boxes & Transfer Hatches

Move materials between cleanroom zones with fewer personnel entries. Explore static, HEPA-filtered, VHP and specialized pass boxes, with chamber sizes, door layouts and transfer arrangements suited to your payload and process.

19pass boxes and transfer chambers
19 Transfer ConfigurationsStatic stainless steel cleanroom pass box on a white background
01Define payload dimensions, weight, packaging and transfer frequency.
02Identify room pressure relationship and the acceptable direction of leakage.
03Confirm whether airflow, particle removal, surface treatment or temperature control is required.
04Provide wall construction, installation height, door arrangement and available utilities.
Selection Matrix

How to Select Pass Boxes & Transfer Hatches

Start with the operating task and site constraints, then compare the product direction that best matches the intended use.

Buyer requirementProduct directionWhy it helps
Simple transfer between compatible clean zonesStatic pass box or transfer hatchPayload size and door interlocking
Filtered chamber without site ductworkSelf-contained HEPA pass boxPower and filter service access
Continuous controlled airflow over payloadDynamic or unidirectional-flow pass boxAirflow direction and room pressures
Remove loose particles from compatible packagesMaterial air-shower pass boxPackaging durability and cycle time
Timed accessible-surface treatmentUV-C material treatment pass boxShadowing and material compatibility
VHP-compatible transfer cycleVHP pass boxCycle interfaces, sealing and aeration
Containment or controlled leakage directionBiosafety, negative- or positive-pressure pass boxSupply/exhaust strategy and service access
Large, refrigerated or special-area transferApplication-specific chamberPayload, temperature and project conditions

Compare 19 Pass Boxes & Transfer Hatches

Narrow your choices by the features that matter to your application. View specifications and add suitable models to your inquiry list for a tailored quote.

19 models shown
Static Cleanroom Pass Box main product view

Kotak Pass Cleanroom Statik

A non-ventilated stainless transfer cabinet that separates two rooms through sealed, interlocked doors.

StaticInterlockedWall-mounted
View Model →
Material Air-Shower Pass Box main product view

Bahan Kotak Air-Shower Pass

A timed material chamber that uses filtered cleaning jets and return grilles to remove loose particles from compatible packages.

Air showerMaterial cleaningTimed cycle
View Model →
UV-C Material Treatment Pass Box main product view

UV-C Material Treatment Pass Box

An interlocked transfer chamber with shielded UV-C lamps for timed treatment of accessible surfaces on compatible materials.

UV-CTimed treatmentInterlocked
View Model →
Hazardous-Area Pass Box main product view

Kotak Pass Daerah Berbahaya

A configurable sealed pass box for controlled transfer at hazardous process boundaries, without assigning a specific area classification.

Hazardous processSealedProject review
View Model →
High-Seal Stainless Steel Pass Box main product view

Kotak Stainless Steel Pass Segel Tinggi

A high-seal stainless transfer chamber with compression-gasket doors for moving materials across critical pressure or containment boundaries.

High sealStainless steelCompression gasket
View Model →
Laboratory Specimen Pass Box main product view

Laboratorium Specimen Pass Box

A compact interlocked chamber with a removable sample tray for controlled transfer of labelled specimens between collection and laboratory areas.

LaboratorySpecimensRemovable tray
View Model →
No models match every selected filter.
Reset one or more filters to compare a broader group.
Solutions for Your Application

Overcome the Challenges in Your Process

A pass box should be selected around the payload, room pressure relationship and required chamber process rather than by external size alone.

An underspecified chamber can create bypass risk, poor loading ergonomics, incompatible treatment or unnecessary transfer delays.Coordinate payload envelope, airflow or treatment method, sealing, interlock logic and service access as one transfer workflow.
The payload fits the opening but cannot be loaded safely at the installed height.Confirm the complete payload envelope, weight and handling method before fixing chamber size, sill height or a floor-standing arrangement.
Door opening disturbs the intended pressure relationship between adjacent rooms.Coordinate door interlocking, chamber leakage direction and any filtered supply or exhaust with the actual room pressure cascade.
A treatment cycle does not reach shadowed surfaces or is incompatible with the transferred packaging.Review payload orientation, exposed surfaces and material compatibility before selecting UV-C, VHP or air-shower treatment.
Filters, lamps or control components cannot be serviced after the pass box is built into the wall.Define service side, removable panels, utility connections and replacement clearances during opening and wall-interface coordination.
Get a Tailored Quote

Tell Us What Your Application Needs

  • Payload dimensions and weight
  • Transfer frequency and direction
  • Adjacent-room pressure relationship
  • Required airflow or treatment process
  • Wall opening and installation height
  • Door number and orientation
  • Available power, ductwork and services
  • Destination and project stage
Common Questions

Before choosing Pass Boxes & Transfer Hatches

A static pass box provides an interlocked transfer chamber without active recirculating airflow. A dynamic model adds filtered airflow to control the chamber environment during transfer.

Pressure control is considered when the transfer boundary must favour payload protection or containment. The adjacent-room pressures and exhaust or supply strategy must be reviewed together.

Yes. Floor-standing and large transfer chambers can be coordinated around the payload envelope, handling height, door arrangement and available structural opening.

No. Treatment selection depends on material compatibility, surface exposure, packaging and the intended process. Those conditions must be confirmed for each project.

Get a Pass Box Matched to Your Transfer Process

Share your payload dimensions, room conditions and transfer frequency. We will help you choose a suitable chamber configuration and quote your requirements.

Request a Pass Box Quote →
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami