Control de volumen manual Damper
- Locking Manual Quadrant
- Opposed 3V Blade Bank
- Concealed Frame Linkage
- Permanent Branch Balancing
Introducción del producto
The manual volume control damper places a bank of linked 3V blades inside a rigid galvanized channel frame. Turning the external quadrant rotates the blade shafts together, allowing the balancing technician to establish the required branch resistance and then lock the position mechanically. Opposed blade motion provides more even downstream velocity distribution than a single flap at intermediate positions. The drive linkage is enclosed within the frame, leaving the airway clear and protecting moving parts from accidental contact.
Características clave
Opposed 3V blades divide the throttling area across the full frame for smoother branch balancing.
Concealed linkage reduces obstruction in the airway and shields connecting bars from handling damage.
Channel-frame flange options support duct insertion, surface mounting or connection to an equipment opening.
Preocupaciones del producto del cliente
A manual damper should give the balancer fine position control, remain locked after commissioning and avoid creating a severely biased downstream velocity profile.
Aplicaciones típicas
Parámetros técnicos
Typical construction data for a galvanized rectangular manual balancing damper are listed below.
| Materiales Core | Galvanized-steel 3V blades with plated steel shafts, concealed linkage and polymer bearings |
|---|---|
| Panel de espesor | 1.5 mm formed galvanized control blades |
| Ancho efectivo | 152–1219 mm nominal single-section frame width |
| Longitud máxima | Up to 1880 mm single-section frame height |
| Acero frente a espesor | 1.5 mm galvanized channel frame |
| Densidad Core | Approximately 7850 kg/m³ for galvanized steel blades |
| Conductividad térmica | Approximately 45–55 W/(m·K) for the carbon-steel blade material |
| Superficie acabada | Mill-galvanized blade and frame surfaces with zinc-plated operating hardware |
| Tipo conjunto | Flanged channel frame with linked opposed blades and external locking quadrant |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Manual Volume Control Damper specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita