Manuelle Volume Control Damper
- Locking Manual Quadrant
- Opposed 3V Blade Bank
- Concealed Frame Linkage
- Permanent Branch Balancing
Produkteinführung
The manual volume control damper places a bank of linked 3V blades inside a rigid galvanized channel frame. Turning the external quadrant rotates the blade shafts together, allowing the balancing technician to establish the required branch resistance and then lock the position mechanically. Opposed blade motion provides more even downstream velocity distribution than a single flap at intermediate positions. The drive linkage is enclosed within the frame, leaving the airway clear and protecting moving parts from accidental contact.
Key Features
Opposed 3V blades divide the throttling area across the full frame for smoother branch balancing.
Concealed linkage reduces obstruction in the airway and shields connecting bars from handling damage.
Channel-frame flange options support duct insertion, surface mounting or connection to an equipment opening.
Kunden Produktbedenken
A manual damper should give the balancer fine position control, remain locked after commissioning and avoid creating a severely biased downstream velocity profile.
Typische Anwendungen
Technische Parameter
Typical construction data for a galvanized rectangular manual balancing damper are listed below.
| Core Material | Galvanized-steel 3V blades with plated steel shafts, concealed linkage and polymer bearings |
|---|---|
| Panel Dicke | 1.5 mm formed galvanized control blades |
| Effektive Breite | 152–1219 mm nominal single-section frame width |
| Maximale Länge | Up to 1880 mm single-section frame height |
| Stahl facing Dicke | 1.5 mm galvanized channel frame |
| Kerndichte | Approximately 7850 kg/m³ for galvanized steel blades |
| Thermische Leitfähigkeit | Approximately 45–55 W/(m·K) for the carbon-steel blade material |
| Oberfläche Finish | Mill-galvanized blade and frame surfaces with zinc-plated operating hardware |
| Gemeinsamer Typ | Flanged channel frame with linked opposed blades and external locking quadrant |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Manual Volume Control Damper specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch