Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

Датчик токсичных газов

A fixed electrochemical gas detector configured for a selected toxic gas and installed near credible release points in cleanroom support or process areas.
  • Gas-Specific Sensor Cartridge
  • Local and Remote Alarms
  • Replaceable Electrochemical Cell
  • Protected Diffusion Inlet
Запрос котировки Просмотреть продукты

Введение продукции

The fixed toxic gas detector uses a gas-specific electrochemical cartridge selected for the target hazard, such as ammonia, chlorine, hydrogen sulfide or carbon monoxide. Ambient gas diffuses through a hydrophobic filter to the electrodes, generating a concentration-proportional signal. The transmitter provides local indication, configurable alarm relays and a standard analog or digital output. Sensor cartridges can be replaced independently of the housing, and optional remote sensing heads place the element closer to the expected release location.

Основные характеристики

Target-specific electrochemical cartridges provide selective response for the chosen toxic gas.

A hydrophobic diffusion barrier protects the cell from droplets while admitting gas.

Independent warning and alarm thresholds operate local indicators and remote interlocks.

Replaceable cartridges and remote-head options simplify lifecycle and location changes.

Обеспокоенность клиентов продуктами

Toxic gas monitoring must match the actual gas, likely release behavior and potential sensor cross-sensitivities rather than using one generic detector.

A detector selected for the wrong gas has weak or misleading response.A gas-specific cartridge is chosen for the target compound and expected concentration range.
The detector is mounted where air movement carries the gas away from it.Release analysis and gas-density behavior determine sensor position near credible accumulation paths.
Cross-sensitive vapors trigger nuisance alarms during cleaning.Gas-specific selection, alarm delay and known interference review reduce avoidable responses.
An expired cell remains installed because replacement requires rewiring.A plug-in sensor cartridge can be exchanged while retaining the mounted transmitter and field cable.

Типичные приложения

Process gas cabinetsChemical storage support roomsSterilant handling areasClean utility equipment rooms

Технические параметры

Typical construction values for a fixed cleanroom toxic gas detector are shown below.

Основной материалGas-specific electrochemical cartridge in powder-coated aluminum transmitter with stainless steel sensor guard
Толщина панели60-110 mm detector depth
эффективная ширина120-200 mm housing width
Максимальная длинаUp to 280 mm detector height
Толщина линий стали0.5-1.0 mm stainless sensor guard and mounting plate
Плотность ядра2650-2750 kg/m³ for aluminum transmitter body
Теплопроводимость150-220 W/(m·K) for aluminum enclosure material
Поверхностная отделкаWhite or light-gray powder-coated aluminum body with gas-specific color label, black display and red alarm indicator
Объединенный типPlug-in diffusion cartridge with sealed cable entry and removable alarm-output terminal
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Gas-specific cartridge selectionLocal display and sounderRemote sensing headAnalog, relay or digital outputs

Planning a Toxic Gas Sensor specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты