有毒ガスセンサー

A fixed electrochemical gas detector configured for a selected toxic gas and installed near credible release points in cleanroom support or process areas.
  • Gas-Specific Sensor Cartridge
  • Local and Remote Alarms
  • Replaceable Electrochemical Cell
  • Protected Diffusion Inlet
見積もりリクエスト 製品案内

商品紹介

The fixed toxic gas detector uses a gas-specific electrochemical cartridge selected for the target hazard, such as ammonia, chlorine, hydrogen sulfide or carbon monoxide. Ambient gas diffuses through a hydrophobic filter to the electrodes, generating a concentration-proportional signal. The transmitter provides local indication, configurable alarm relays and a standard analog or digital output. Sensor cartridges can be replaced independently of the housing, and optional remote sensing heads place the element closer to the expected release location.

主要な特徴

Target-specific electrochemical cartridges provide selective response for the chosen toxic gas.

A hydrophobic diffusion barrier protects the cell from droplets while admitting gas.

Independent warning and alarm thresholds operate local indicators and remote interlocks.

Replaceable cartridges and remote-head options simplify lifecycle and location changes.

お客様の製品に関する懸念事項

Toxic gas monitoring must match the actual gas, likely release behavior and potential sensor cross-sensitivities rather than using one generic detector.

A detector selected for the wrong gas has weak or misleading response.A gas-specific cartridge is chosen for the target compound and expected concentration range.
The detector is mounted where air movement carries the gas away from it.Release analysis and gas-density behavior determine sensor position near credible accumulation paths.
Cross-sensitive vapors trigger nuisance alarms during cleaning.Gas-specific selection, alarm delay and known interference review reduce avoidable responses.
An expired cell remains installed because replacement requires rewiring.A plug-in sensor cartridge can be exchanged while retaining the mounted transmitter and field cable.

典型的な用途

Process gas cabinetsChemical storage support roomsSterilant handling areasClean utility equipment rooms

技術的なパラメータ

Typical construction values for a fixed cleanroom toxic gas detector are shown below.

コア材料Gas-specific electrochemical cartridge in powder-coated aluminum transmitter with stainless steel sensor guard
パネルの厚さ60-110 mm detector depth
有効幅120-200 mm housing width
最大長さUp to 280 mm detector height
鋼鉄の厚さを直面する0.5-1.0 mm stainless sensor guard and mounting plate
コア密度2650-2750 kg/m³ for aluminum transmitter body
熱伝導率150-220 W/(m·K) for aluminum enclosure material
表面仕上げWhite or light-gray powder-coated aluminum body with gas-specific color label, black display and red alarm indicator
ジョイントタイプPlug-in diffusion cartridge with sealed cable entry and removable alarm-output terminal
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Gas-specific cartridge selectionLocal display and sounderRemote sensing headAnalog, relay or digital outputs

Planning a Toxic Gas Sensor specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。