클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

독성 가스 센서

A fixed electrochemical gas detector configured for a selected toxic gas and installed near credible release points in cleanroom support or process areas.
  • Gas-Specific Sensor Cartridge
  • Local and Remote Alarms
  • Replaceable Electrochemical Cell
  • Protected Diffusion Inlet
견적 요청 제품 찾아보기

상품 소개

The fixed toxic gas detector uses a gas-specific electrochemical cartridge selected for the target hazard, such as ammonia, chlorine, hydrogen sulfide or carbon monoxide. Ambient gas diffuses through a hydrophobic filter to the electrodes, generating a concentration-proportional signal. The transmitter provides local indication, configurable alarm relays and a standard analog or digital output. Sensor cartridges can be replaced independently of the housing, and optional remote sensing heads place the element closer to the expected release location.

주요 기능

Target-specific electrochemical cartridges provide selective response for the chosen toxic gas.

A hydrophobic diffusion barrier protects the cell from droplets while admitting gas.

Independent warning and alarm thresholds operate local indicators and remote interlocks.

Replaceable cartridges and remote-head options simplify lifecycle and location changes.

고객 제품 관심사

Toxic gas monitoring must match the actual gas, likely release behavior and potential sensor cross-sensitivities rather than using one generic detector.

A detector selected for the wrong gas has weak or misleading response.A gas-specific cartridge is chosen for the target compound and expected concentration range.
The detector is mounted where air movement carries the gas away from it.Release analysis and gas-density behavior determine sensor position near credible accumulation paths.
Cross-sensitive vapors trigger nuisance alarms during cleaning.Gas-specific selection, alarm delay and known interference review reduce avoidable responses.
An expired cell remains installed because replacement requires rewiring.A plug-in sensor cartridge can be exchanged while retaining the mounted transmitter and field cable.

일반적인 응용 프로그램

Process gas cabinetsChemical storage support roomsSterilant handling areasClean utility equipment rooms

기술 매개변수

Typical construction values for a fixed cleanroom toxic gas detector are shown below.

핵심 재료Gas-specific electrochemical cartridge in powder-coated aluminum transmitter with stainless steel sensor guard
패널 두께60-110 mm detector depth
유효 폭120-200 mm housing width
최대 길이Up to 280 mm detector height
강철 면면 두께0.5-1.0 mm stainless sensor guard and mounting plate
코어 밀도2650-2750 kg/m³ for aluminum transmitter body
열전도도 (Thermal Conductivity)150-220 W/(m·K) for aluminum enclosure material
표면 마무리White or light-gray powder-coated aluminum body with gas-specific color label, black display and red alarm indicator
접합 유형Plug-in diffusion cartridge with sealed cable entry and removable alarm-output terminal
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Gas-specific cartridge selectionLocal display and sounderRemote sensing headAnalog, relay or digital outputs