Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

Датчик влажности

A capacitive relative-humidity sensor that measures cleanroom moisture with a protected sensing element and serviceable wall or duct housing.
  • Capacitive RH Measurement
  • Replaceable Sensor Filter
  • Low-Drift Signal Conditioning
  • Wall or Duct Format
Запрос котировки Просмотреть продукты

Введение продукции

The cleanroom humidity sensor uses a capacitive polymer element whose electrical response changes with water-vapor concentration. A protective membrane or porous filter shields the element from particles and incidental contact while allowing moisture diffusion. Signal conditioning linearizes and temperature-compensates the RH output for connection to environmental monitoring or HVAC controls. Wall versions use a compact ventilated enclosure; duct versions place a filtered probe into the airstream while keeping wiring accessible outside the duct.

Основные характеристики

Capacitive sensing responds across normal cleanroom humidity ranges without a moving mechanism.

A replaceable filter protects the sensitive element from dust and handling contamination.

Temperature compensation reduces humidity error caused by normal room-temperature variation.

Wall and duct formats place the same sensing principle at the appropriate measurement location.

Обеспокоенность клиентов продуктами

Humidity measurement is vulnerable to contamination, local condensation and unsuitable mounting locations that do not represent the room air.

Cleaning residue coats the humidity element and causes slow drift.A replaceable protective filter reduces direct contamination and simplifies service.
Condensation temporarily saturates the sensor after a cold-air event.A hydrophobic filter and appropriate probe placement reduce liquid-water contact.
A wall pocket measures stagnant air rather than the occupied zone.Ventilated housing and considered mounting height expose the element to representative circulation.
Long field wiring adds noise to a low-level sensor signal.Integrated active signal conditioning provides a robust current, voltage or digital output.

Типичные приложения

Cleanroom relative humidity monitoringAHU supply-air measurementStability roomsElectronics humidity control

Технические параметры

Typical materials and dimensions for a cleanroom capacitive humidity sensor are listed below.

Основной материалCapacitive polymer RH element with hydrophobic membrane in polycarbonate wall or probe housing
Толщина панели25-45 mm wall-sensor depth
эффективная ширина80-120 mm wall housing width
Максимальная длинаDuct probes up to 300 mm
Толщина линий стали0-0.8 mm; optional stainless probe tube
Плотность ядра1180-1220 kg/m³ for polycarbonate housing
Теплопроводимость0.19-0.22 W/(m·K) for polycarbonate enclosure material
Поверхностная отделкаSmooth white wall housing or satin stainless probe with white electronics head
Объединенный типSnap-fit wall enclosure or threaded duct flange with replaceable filtered sensor cap
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Wall or duct probeVoltage, current or digital outputReplaceable membrane filterRemote probe cable

Planning a Humidity Sensor specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты