Sistema de Controle de Pressão de Sala
- Fast Pressure Response
- Door-Aware Control Logic
- Supply and Exhaust Coordination
- Local Pressure Display
Introdução do produto
The room pressure control system combines a low-range differential pressure sensor, room controller, modulating airflow device and local display. It regulates the offset between supply and exhaust so the room remains positive or negative relative to its reference space. Door contacts allow the controller to suspend aggressive correction while a door is open, avoiding actuator hunting and airflow overshoot. The local display gives occupants immediate status while the network interface sends pressure, alarms and operating mode to the supervisory system.
Características-chave
Door-open logic reduces unnecessary damper movement during normal personnel passage.
Cascade control can coordinate supply and exhaust devices around a defined airflow offset.
Local indication and remote network values present the same room condition to users and operators.
Preocupações do produto do cliente
Room pressure can change within seconds when a door opens, an exhaust device changes state or an airflow path becomes restricted.
Aplicações típicas
Parâmetros técnicos
Typical enclosure and sensing-package construction for cleanroom room pressure control is shown below.
| Material principal | Flame-retardant polycarbonate room controller with MEMS pressure sensor and powder-coated steel damper panel |
|---|---|
| Painel de espessura | 45-120 mm controller and display depth |
| Largura efetiva | 120-240 mm room display width |
| Comprimento máximo | Up to 300 mm display or controller height |
| Aço enfrentando espessura | 1.0-1.5 mm for the optional steel control enclosure |
| Densidade Core | 1180-1220 kg/m³ for polycarbonate housing parts |
| Condutividade térmica | 0.19-0.22 W/(m·K) for polycarbonate housing material |
| Superfície acabado | Smooth white polycarbonate display face with blue backlit status screen |
| Tipo conjunto | Flush wall display with barbed pressure ports, pluggable terminals and network connector |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Room Pressure Control System specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã