Room 圧力制御システム

A fast room-level control package that compares differential pressure with setpoint and modulates supply or exhaust airflow to preserve the intended pressure cascade.
  • Fast Pressure Response
  • Door-Aware Control Logic
  • Supply and Exhaust Coordination
  • Local Pressure Display
見積もりリクエスト 製品案内

商品紹介

The room pressure control system combines a low-range differential pressure sensor, room controller, modulating airflow device and local display. It regulates the offset between supply and exhaust so the room remains positive or negative relative to its reference space. Door contacts allow the controller to suspend aggressive correction while a door is open, avoiding actuator hunting and airflow overshoot. The local display gives occupants immediate status while the network interface sends pressure, alarms and operating mode to the supervisory system.

主要な特徴

Low-range differential measurement resolves the small pressure relationships used in cleanrooms.

Door-open logic reduces unnecessary damper movement during normal personnel passage.

Cascade control can coordinate supply and exhaust devices around a defined airflow offset.

Local indication and remote network values present the same room condition to users and operators.

お客様の製品に関する懸念事項

Room pressure can change within seconds when a door opens, an exhaust device changes state or an airflow path becomes restricted.

A door opening causes the controller to drive the airflow device to an extreme position.Door-aware logic holds or limits correction until the doorway disturbance has cleared.
Independent supply and exhaust loops fight each other and destabilize the room.A coordinated airflow offset maintains one consistent pressure-control strategy.
Small pressure changes are hidden by an unsuitable high-range sensor.A dedicated low-differential-pressure transducer provides the resolution needed for room control.
Occupants cannot tell whether the room is safe to enter.A color status display and audible alarm make the current pressure condition visible at the door.

典型的な用途

Positive-pressure pharmaceutical roomsNegative-pressure containment roomsHospital isolation suitesResearch laboratory airlocks

技術的なパラメータ

Typical enclosure and sensing-package construction for cleanroom room pressure control is shown below.

コア材料Flame-retardant polycarbonate room controller with MEMS pressure sensor and powder-coated steel damper panel
パネルの厚さ45-120 mm controller and display depth
有効幅120-240 mm room display width
最大長さUp to 300 mm display or controller height
鋼鉄の厚さを直面する1.0-1.5 mm for the optional steel control enclosure
コア密度1180-1220 kg/m³ for polycarbonate housing parts
熱伝導率0.19-0.22 W/(m·K) for polycarbonate housing material
表面仕上げSmooth white polycarbonate display face with blue backlit status screen
ジョイントタイプFlush wall display with barbed pressure ports, pluggable terminals and network connector
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Positive or negative pressure modeSupply or exhaust damper controlDoor contact integrationBACnet or Modbus communication