Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Equipamento de sala limpa Peças de reposição

Z Controlador de bloqueio Pass Box

A compact electronic module that coordinates two pass box doors, lock outputs, status indication and timed transfer sequences.
  • Two-Door Interlock Logic
  • Visible Status Indication
  • Removable Terminal Blocks
  • Service-Friendly Replacement
Solicite um orçamento. Browse produtos

Introdução do produto

The pass box interlock controller is the central logic module for a two-door cleanroom transfer chamber. It reads door-position and request signals, energizes the appropriate electric lock, prevents both doors from being released together and provides local operating status. A compact flame-retardant enclosure, removable screw terminals and plug connectors simplify replacement inside an equipment compartment. Electrical supply, input type, lock voltage, output loading, timing logic and connector pinout must be matched to the existing pass box before installation.

Características-chave

Dedicated logic prevents simultaneous release of opposing pass box doors.

A numeric display and separate status LEDs support rapid operating checks.

Removable terminal blocks allow field wiring to remain organized during module replacement.

Membrane keys provide local access to timing and operating adjustments without an external programmer.

Preocupações do produto do cliente

A replacement controller must reproduce the existing door sequence and electrical interfaces without defeating the transfer chamber interlock.

Incorrect interlock logic can permit both doors to unlock at the same time.Two-door sequencing is configured so one release output remains inhibited while the opposite door is open or unlocked.
An incompatible lock output may overload the controller or fail to release the door.Supply voltage, output type and allowable load are matched to the installed electromagnetic or electric-bolt locks.
Unclear fault status makes a failed sensor difficult to distinguish from a lock problem.Display and indicator states provide direct feedback for door requests, interlock state and connected input conditions.
Rewiring a replacement module increases downtime and connection errors.Detachable terminal blocks and keyed plug interfaces support labeled, one-for-one service replacement.

Aplicações típicas

Static cleanroom pass boxesDynamic pass-through chambersMaterial transfer hatchesReplacement controls for interlocked transfer cabinets

Parâmetros técnicos

Typical construction and integration ranges for pass box interlock control modules are shown below.

Material principalFlame-retardant engineering-plastic enclosure with printed circuit assembly and copper terminals
Painel de espessura25-55 mm nominal controller enclosure depth
Largura efetiva90-180 mm nominal module width
Comprimento máximoUp to 240 mm overall length including terminal and plug clearance
Aço enfrentando espessura0.8-1.5 mm for optional galvanized mounting plate
Densidade Core1150-1450 kg/m³ for the engineering-plastic enclosure
Condutividade térmica0.20-0.35 W/(m·K) for the enclosure material
Superfície acabadoTextured black molded housing with green removable terminals and white keyed connectors
Tipo conjuntoScrew-terminal field connections with keyed multi-pin plug interfaces and flange mounting
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Matched AC or DC supply inputElectromagnetic-lock or electric-bolt output logicBuzzer and indicator-light interfacesCustom timing and connector pinout

Planning a Pass Box Interlock Controller specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat