Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Equipamento de descontaminação de pessoal e materiais / Negative-Pressure Containment Pass Box
Equipamento de descontaminação de pessoal e materiais

Caixa de passagem de contenção de pressão negativa

A transfer chamber held below adjacent-room pressure so leakage is drawn inward and routed to filtered exhaust.
  • Negative Chamber Bias
  • Filtered Exhaust
  • Controlled Make-Up Air
  • Pressure-Gated Interlocks
Solicite um orçamento. Browse produtos

Introdução do produto

The negative-pressure containment pass box moves dusty, potent or odorous material without allowing a passive leak towards the support space. A variable-speed exhaust fan maintains the selected negative pressure, while a controlled make-up path avoids excessive suction at the door seals. A pressure signal controls the interlock logic and indicates when the chamber has recovered after a transfer.

Características-chave

Closed-loop fan control responds to the measured chamber pressure.

A deliberate make-up air path limits high-velocity leakage through random gaps.

The clean-side door can remain inhibited until pressure recovers.

A sealed final-filter service panel separates captured material from the corridor.

Smooth welded internal surfaces support wipe-down after transfer.

Preocupações do produto do cliente

The chamber needs to keep leakage inward without making doors difficult to operate or disrupting adjacent spaces.

Exhaust force makes a door difficult to unlatch.Controlled make-up air and an adjustable setpoint limit the differential pressure.
Filter loading reduces extraction and reverses the leakage direction.Pressure-responsive fan control adjusts airflow as resistance changes.
Captured powder is exposed during routine filter service.A gasketed service housing keeps handling on the designated dirty side.
The next door opens before the chamber recovers.Pressure-gated interlocks delay release until the selected negative bias returns.

Aplicações típicas

Potent compound transferPowder dispensing roomsHazardous sample handlingOdour-controlled process suites

Parâmetros técnicos

Typical pressure-containment construction ranges for a negative-pressure pass box are listed below.

Material principalWelded SUS 304 or SUS 316L chamber with variable-speed exhaust, make-up inlet and HEPA final filter
Painel de espessura80-150 mm sealed plenum and double-wall construction
Largura efetiva500-1200 mm clear chamber width
Comprimento máximoUp to 1500 mm chamber depth
Aço enfrentando espessura1.2-1.5 mm stainless-steel facing
Densidade Core35-40 kg/m³ polyurethane insulation around pressure and filter plenums
Condutividade térmica0.022-0.028 W/(m·K) for polyurethane plenum insulation
Superfície acabadoBrushed or electropolished stainless chamber with smooth coved internal corners
Tipo conjuntoPressure-tight welded body with gasketed interlocked doors and sealed filter-service panel
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Typical -10 to -50 Pa pressure rangeSafe-change exhaust filterRemote alarm contactsRoom-specific pressure setpoint