Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Z Sistema de alarme central para sala limpa

A dedicated alarm annunciation platform that consolidates room, equipment, door and utility events into prioritized visual, audible and remote notifications.
  • Priority-Based Annunciation
  • First-Out Event Capture
  • Zone Alarm Mapping
  • Remote Notification Outputs
Solicite um orçamento. Browse produtos

Introdução do produto

The cleanroom central alarm system receives dry contacts, analog alarm states and network events from environmental instruments and supporting equipment. A color touchscreen and physical audible-visual devices distinguish critical alarms from warnings and maintenance notices. First-out sequencing identifies the initiating event before secondary conditions appear, while acknowledgement, silence and reset remain separate operator actions. Local alarm panels can be distributed by suite and connected to a central workstation without replacing the independent alarm functions at each room.

Características-chave

First-out chronology highlights the event that initiated a chain of related alarms.

Distinct colors and sound patterns separate critical, warning and advisory priorities.

Zone maps direct responders to the affected room, airlock, utility or equipment item.

Isolated relay and network outputs route selected alarms to BMS, EMS or remote dialers.

Preocupações do produto do cliente

A central alarm system must make the first actionable condition obvious without suppressing local room-level warnings.

Many alarms appear together and operators cannot identify the initiating fault.First-out sequencing and synchronized timestamps preserve the original event order.
All events use the same buzzer and receive the same response.Priority-specific colors, sounds and routing distinguish urgent excursions from maintenance notices.
Responders know an alarm exists but not where it originated.Room and equipment maps connect each alarm point to a clear physical location.
Silencing a horn is confused with clearing the alarm condition.Separate acknowledge, silence and reset functions preserve alarm state until the input returns normal.

Aplicações típicas

Pharmaceutical production suitesBiocontainment facilitiesMedical cleanroom campusesSemiconductor utility monitoring

Parâmetros técnicos

Typical construction values for a centralized cleanroom alarm annunciator cabinet are listed below.

Material principalPowder-coated steel enclosure with FR-4 annunciator boards, copper relay contacts and industrial touchscreen
Painel de espessura180-350 mm cabinet depth
Largura efetiva500-1000 mm panel width
Comprimento máximoUp to 1800 mm panel height
Aço enfrentando espessura1.2-1.8 mm powder-coated steel panels
Densidade Core7800-8050 kg/m³ for steel enclosure components
Condutividade térmica45-60 W/(m·K) for steel structural panels
Superfície acabadoLight-gray powder coating with color HMI, red beacon and labeled silence-reset controls
Tipo conjuntoGasketed cabinet with pluggable alarm inputs, isolated relay outputs and network gateway
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Touchscreen or LED annunciatorFirst-out alarm logicSMS and email gatewayRedundant power supply