Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

Центральная система сигнализации в чистых помещениях

A dedicated alarm annunciation platform that consolidates room, equipment, door and utility events into prioritized visual, audible and remote notifications.
  • Priority-Based Annunciation
  • First-Out Event Capture
  • Zone Alarm Mapping
  • Remote Notification Outputs
Запрос котировки Просмотреть продукты

Введение продукции

The cleanroom central alarm system receives dry contacts, analog alarm states and network events from environmental instruments and supporting equipment. A color touchscreen and physical audible-visual devices distinguish critical alarms from warnings and maintenance notices. First-out sequencing identifies the initiating event before secondary conditions appear, while acknowledgement, silence and reset remain separate operator actions. Local alarm panels can be distributed by suite and connected to a central workstation without replacing the independent alarm functions at each room.

Основные характеристики

First-out chronology highlights the event that initiated a chain of related alarms.

Distinct colors and sound patterns separate critical, warning and advisory priorities.

Zone maps direct responders to the affected room, airlock, utility or equipment item.

Isolated relay and network outputs route selected alarms to BMS, EMS or remote dialers.

Обеспокоенность клиентов продуктами

A central alarm system must make the first actionable condition obvious without suppressing local room-level warnings.

Many alarms appear together and operators cannot identify the initiating fault.First-out sequencing and synchronized timestamps preserve the original event order.
All events use the same buzzer and receive the same response.Priority-specific colors, sounds and routing distinguish urgent excursions from maintenance notices.
Responders know an alarm exists but not where it originated.Room and equipment maps connect each alarm point to a clear physical location.
Silencing a horn is confused with clearing the alarm condition.Separate acknowledge, silence and reset functions preserve alarm state until the input returns normal.

Типичные приложения

Pharmaceutical production suitesBiocontainment facilitiesMedical cleanroom campusesSemiconductor utility monitoring

Технические параметры

Typical construction values for a centralized cleanroom alarm annunciator cabinet are listed below.

Основной материалPowder-coated steel enclosure with FR-4 annunciator boards, copper relay contacts and industrial touchscreen
Толщина панели180-350 mm cabinet depth
эффективная ширина500-1000 mm panel width
Максимальная длинаUp to 1800 mm panel height
Толщина линий стали1.2-1.8 mm powder-coated steel panels
Плотность ядра7800-8050 kg/m³ for steel enclosure components
Теплопроводимость45-60 W/(m·K) for steel structural panels
Поверхностная отделкаLight-gray powder coating with color HMI, red beacon and labeled silence-reset controls
Объединенный типGasketed cabinet with pluggable alarm inputs, isolated relay outputs and network gateway
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Touchscreen or LED annunciatorFirst-out alarm logicSMS and email gatewayRedundant power supply

Planning a Cleanroom Central Alarm System specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat