Blower Filter Unit (BFU)
- High-Pressure Centrifugal Blower
- Ducted or Recirculating Inlet
- Perforated Air Diffuser
- Large Airflow Capacity
Introdução do produto
The blower filter unit houses a forward- or backward-curved centrifugal blower above a full-size HEPA or ULPA filter in a deep insulated enclosure. Unlike a shallow grid FFU, the BFU is designed with enough chamber height for a larger scroll or blower wheel and can accept a round duct collar, inlet damper or recirculating top intake. An internal perforated plate distributes the higher-volume discharge over the filter surface. The format is suited to turbulent-flow rooms, high air-change zones and ceiling positions where a long duct path or loaded filter creates more resistance than a compact FFU can handle.
Características-chave
The large pressure chamber reduces direct fan imprint before air reaches the HEPA or ULPA surface.
A removable perforated plate smooths the discharge and protects the downstream filter face during service.
Duct-connected and self-recirculating intake arrangements use the same ceiling-mounted enclosure platform.
Preocupações do produto do cliente
Compact FFUs can lose airflow when the air path includes long ducts, dampers or a heavily loaded final filter.
Aplicações típicas
Parâmetros técnicos
Typical BFU enclosure and filter ranges for cleanroom ceiling service are shown below.
| Material principal | Centrifugal blower, micro-glass HEPA or ULPA filter and optional closed-cell acoustic liner |
|---|---|
| Painel de espessura | 500-750 mm overall housing depth |
| Largura efetiva | 650-1300 mm nominal ceiling module width |
| Comprimento máximo | Up to 1450 mm standard housing length |
| Aço enfrentando espessura | 1.0-1.5 mm powder-coated steel or 304 stainless-steel blower-filter casing |
| Densidade Core | Approximately 24-48 kg/m³ density for optional closed-cell acoustic insulation |
| Condutividade térmica | Approximately 0.033-0.040 W/(m·K) for the optional closed-cell acoustic liner |
| Superfície acabado | Ivory-white powder coat or brushed 304 stainless steel with stainless perforated diffuser |
| Tipo conjunto | Flanged duct inlet with gasketed blower access panel and compression-seal or gel-seal final filter |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Blower Filter Unit (BFU) specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.