موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
FFU ومعدات تنقية الهواء الطرفية

وحدة تصفية منفاخ (BFU)

A deeper ceiling clean-air unit using a dedicated centrifugal blower to overcome duct, damper and final-filter resistance at elevated airflow.
  • High-Pressure Centrifugal Blower
  • Ducted or Recirculating Inlet
  • Perforated Air Diffuser
  • Large Airflow Capacity
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The blower filter unit houses a forward- or backward-curved centrifugal blower above a full-size HEPA or ULPA filter in a deep insulated enclosure. Unlike a shallow grid FFU, the BFU is designed with enough chamber height for a larger scroll or blower wheel and can accept a round duct collar, inlet damper or recirculating top intake. An internal perforated plate distributes the higher-volume discharge over the filter surface. The format is suited to turbulent-flow rooms, high air-change zones and ceiling positions where a long duct path or loaded filter creates more resistance than a compact FFU can handle.

الخصائص الرئيسية

A dedicated centrifugal blower develops useful static pressure for ducted inlets, dampers and deeper final filters.

The large pressure chamber reduces direct fan imprint before air reaches the HEPA or ULPA surface.

A removable perforated plate smooths the discharge and protects the downstream filter face during service.

Duct-connected and self-recirculating intake arrangements use the same ceiling-mounted enclosure platform.

مخاوف المنتج للعملاء

Compact FFUs can lose airflow when the air path includes long ducts, dampers or a heavily loaded final filter.

Supply volume falls below target when duct and terminal pressure losses are added together.The larger centrifugal blower provides a higher available static-pressure range than a shallow axial module.
A concentrated blower outlet produces a visible high-velocity patch at the centre of the diffuser.The deep plenum and perforated equalising plate distribute pressure before final filtration.
A central air handler cannot independently trim airflow to one room or process zone.Each BFU can use its own speed setting or damper to balance the local ceiling supply.
Filter replacement requires dismantling the complete blower housing from above.A separated lower filter section permits the final filter and diffuser to be removed without lifting the blower assembly.

تطبيقات نموذجية

High air-change cleanroomsDucted pharmaceutical supply pointsElectronics packaging roomsFood processing clean zonesLarge clean booths and corridors

المعلمات الفنية

Typical BFU enclosure and filter ranges for cleanroom ceiling service are shown below.

المواد الأساسيةCentrifugal blower, micro-glass HEPA or ULPA filter and optional closed-cell acoustic liner
سمك اللوحة500-750 mm overall housing depth
العرض الفعال650-1300 mm nominal ceiling module width
الحد الأقصى الطولUp to 1450 mm standard housing length
الصلب يواجه سمك1.0-1.5 mm powder-coated steel or 304 stainless-steel blower-filter casing
الكثافة الأساسيةApproximately 24-48 kg/m³ density for optional closed-cell acoustic insulation
الموصلية الحراريةApproximately 0.033-0.040 W/(m·K) for the optional closed-cell acoustic liner
إنهاء السطحIvory-white powder coat or brushed 304 stainless steel with stainless perforated diffuser
نوع المشتركFlanged duct inlet with gasketed blower access panel and compression-seal or gel-seal final filter
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Forward- or backward-curved centrifugal blowerRound duct inlet or recirculating top grilleHEPA H14 or ULPA U15 final filterStepped, inverter or EC airflow control

Planning a Blower Filter Unit (BFU) specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا