وحدة تصفية منفاخ (BFU)
- High-Pressure Centrifugal Blower
- Ducted or Recirculating Inlet
- Perforated Air Diffuser
- Large Airflow Capacity
مقدمة المنتج
The blower filter unit houses a forward- or backward-curved centrifugal blower above a full-size HEPA or ULPA filter in a deep insulated enclosure. Unlike a shallow grid FFU, the BFU is designed with enough chamber height for a larger scroll or blower wheel and can accept a round duct collar, inlet damper or recirculating top intake. An internal perforated plate distributes the higher-volume discharge over the filter surface. The format is suited to turbulent-flow rooms, high air-change zones and ceiling positions where a long duct path or loaded filter creates more resistance than a compact FFU can handle.
الخصائص الرئيسية
The large pressure chamber reduces direct fan imprint before air reaches the HEPA or ULPA surface.
A removable perforated plate smooths the discharge and protects the downstream filter face during service.
Duct-connected and self-recirculating intake arrangements use the same ceiling-mounted enclosure platform.
مخاوف المنتج للعملاء
Compact FFUs can lose airflow when the air path includes long ducts, dampers or a heavily loaded final filter.
تطبيقات نموذجية
المعلمات الفنية
Typical BFU enclosure and filter ranges for cleanroom ceiling service are shown below.
| المواد الأساسية | Centrifugal blower, micro-glass HEPA or ULPA filter and optional closed-cell acoustic liner |
|---|---|
| سمك اللوحة | 500-750 mm overall housing depth |
| العرض الفعال | 650-1300 mm nominal ceiling module width |
| الحد الأقصى الطول | Up to 1450 mm standard housing length |
| الصلب يواجه سمك | 1.0-1.5 mm powder-coated steel or 304 stainless-steel blower-filter casing |
| الكثافة الأساسية | Approximately 24-48 kg/m³ density for optional closed-cell acoustic insulation |
| الموصلية الحرارية | Approximately 0.033-0.040 W/(m·K) for the optional closed-cell acoustic liner |
| إنهاء السطح | Ivory-white powder coat or brushed 304 stainless steel with stainless perforated diffuser |
| نوع المشترك | Flanged duct inlet with gasketed blower access panel and compression-seal or gel-seal final filter |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Blower Filter Unit (BFU) specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية