Caixa de passagem de biossegurança
- Gas-Tight Opposing Doors
- Negative-Pressure Purge
- Separate Supply and Exhaust HEPA Stages
- VHP-Ready Service Connections
Introdução do produto
The Biosafety Pass Box is a fixed through-wall enclosure for moving closed sample carriers, instruments and packaged supplies across a laboratory containment boundary without opening a personnel route. The selected configuration uses two opposing glazed doors with compression/inflatable EPDM sealing beads and an electrical one-door-at-a-time interlock. One controlled blower draws chamber air through a dedicated exhaust HEPA stage and returns filtered make-up air through a separate supply HEPA stage, allowing the transfer volume to be operated below the adjacent-room pressure when containment is the priority. A local differential-pressure gauge, touchscreen and red-green status lamps show the purge and interlock state before the release sequence continues. The all-welded coved AISI 316L transfer zone is surrounded by an AISI 304 service enclosure and includes two capped connections for a compatible external VHP cycle package. The base product does not claim a universal biosafety level or sterilization result; chamber pressure, purge timing and any biodecontamination cycle are selected and verified for the intended facility process.
Características-chave
Opposing airtight observation doors use reinforced glazing, EPDM sealing beads and a one-door-at-a-time electrical interlock to avoid an unrestricted opening through the wall barrier.
The local pressure gauge, touchscreen and dedicated red-green indicators give operators direct feedback on chamber pressure, purge progress and door-release availability.
Rounded welded interior corners and two capped VHP-ready connections support wipe-down access and an optional validated biodecontamination package without building a sterilizer into every transfer box.
Preocupações do produto do cliente
Containment laboratories need a material route that limits direct room-to-room airflow, keeps contaminated chamber air within a filtered path and makes each door-release condition visible to operators.
Aplicações típicas
Parâmetros técnicos
Typical configurable construction values for the illustrated gas-tight negative-pressure biosafety transfer box are listed below.
| Material principal | All-welded AISI 316L stainless-steel inner chamber with AISI 304 service enclosure, colorless tempered-glass doors, charcoal EPDM seals and two separately gasketed HEPA stages |
|---|---|
| Painel de espessura | 1.5 mm nominal AISI 316L inner-chamber panel |
| Largura efetiva | 610 mm nominal clear chamber width |
| Comprimento máximo | Up to 610 mm nominal clear transfer depth in the selected configuration |
| Aço enfrentando espessura | 1.5 mm nominal AISI 304 external service facing |
| Densidade Core | 8000 kg/m³ for representative AISI 316L stainless-steel components |
| Condutividade térmica | 15 W/(m·K) for representative AISI 316L stainless steel at room temperature |
| Superfície acabado | Neutral silver satin-brushed chamber and enclosure, colorless clear glazing, charcoal-black EPDM and handles, dark-blue screen, green and red status lenses |
| Tipo conjunto | Two opposing gasket-compression glazed doors with a one-door-at-a-time electrical interlock, rear wall flange and a dual-HEPA negative-pressure purge circuit |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Planning a Biosafety Pass Box specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã