Boîte de biosécurité
- Gas-Tight Opposing Doors
- Negative-Pressure Purge
- Separate Supply and Exhaust HEPA Stages
- VHP-Ready Service Connections
Introduction de produit
The Biosafety Pass Box is a fixed through-wall enclosure for moving closed sample carriers, instruments and packaged supplies across a laboratory containment boundary without opening a personnel route. The selected configuration uses two opposing glazed doors with compression/inflatable EPDM sealing beads and an electrical one-door-at-a-time interlock. One controlled blower draws chamber air through a dedicated exhaust HEPA stage and returns filtered make-up air through a separate supply HEPA stage, allowing the transfer volume to be operated below the adjacent-room pressure when containment is the priority. A local differential-pressure gauge, touchscreen and red-green status lamps show the purge and interlock state before the release sequence continues. The all-welded coved AISI 316L transfer zone is surrounded by an AISI 304 service enclosure and includes two capped connections for a compatible external VHP cycle package. The base product does not claim a universal biosafety level or sterilization result; chamber pressure, purge timing and any biodecontamination cycle are selected and verified for the intended facility process.
Key Features
Opposing airtight observation doors use reinforced glazing, EPDM sealing beads and a one-door-at-a-time electrical interlock to avoid an unrestricted opening through the wall barrier.
The local pressure gauge, touchscreen and dedicated red-green indicators give operators direct feedback on chamber pressure, purge progress and door-release availability.
Rounded welded interior corners and two capped VHP-ready connections support wipe-down access and an optional validated biodecontamination package without building a sterilizer into every transfer box.
Préoccupations du client produit
Containment laboratories need a material route that limits direct room-to-room airflow, keeps contaminated chamber air within a filtered path and makes each door-release condition visible to operators.
Les applications typiques
Paramètres techniques
Typical configurable construction values for the illustrated gas-tight negative-pressure biosafety transfer box are listed below.
| Matériaux de base | All-welded AISI 316L stainless-steel inner chamber with AISI 304 service enclosure, colorless tempered-glass doors, charcoal EPDM seals and two separately gasketed HEPA stages |
|---|---|
| Panneau épaisseur | 1.5 mm nominal AISI 316L inner-chamber panel |
| Largeur effective | 610 mm nominal clear chamber width |
| Longueur maximale | Up to 610 mm nominal clear transfer depth in the selected configuration |
| Acier face épaisseur | 1.5 mm nominal AISI 304 external service facing |
| Densité Core | 8000 kg/m³ for representative AISI 316L stainless-steel components |
| Conductivité thermique | 15 W/(m·K) for representative AISI 316L stainless steel at room temperature |
| surface finie | Neutral silver satin-brushed chamber and enclosure, colorless clear glazing, charcoal-black EPDM and handles, dark-blue screen, green and red status lenses |
| Type joint | Two opposing gasket-compression glazed doors with a one-door-at-a-time electrical interlock, rear wall flange and a dual-HEPA negative-pressure purge circuit |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Biosafety Pass Box specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.