Biosafety Pass Box
- Gas-Tight Opposing Doors
- Negative-Pressure Purge
- Separate Supply and Exhaust HEPA Stages
- VHP-Ready Service Connections
مقدمة المنتج
The Biosafety Pass Box is a fixed through-wall enclosure for moving closed sample carriers, instruments and packaged supplies across a laboratory containment boundary without opening a personnel route. The selected configuration uses two opposing glazed doors with compression/inflatable EPDM sealing beads and an electrical one-door-at-a-time interlock. One controlled blower draws chamber air through a dedicated exhaust HEPA stage and returns filtered make-up air through a separate supply HEPA stage, allowing the transfer volume to be operated below the adjacent-room pressure when containment is the priority. A local differential-pressure gauge, touchscreen and red-green status lamps show the purge and interlock state before the release sequence continues. The all-welded coved AISI 316L transfer zone is surrounded by an AISI 304 service enclosure and includes two capped connections for a compatible external VHP cycle package. The base product does not claim a universal biosafety level or sterilization result; chamber pressure, purge timing and any biodecontamination cycle are selected and verified for the intended facility process.
الخصائص الرئيسية
Opposing airtight observation doors use reinforced glazing, EPDM sealing beads and a one-door-at-a-time electrical interlock to avoid an unrestricted opening through the wall barrier.
The local pressure gauge, touchscreen and dedicated red-green indicators give operators direct feedback on chamber pressure, purge progress and door-release availability.
Rounded welded interior corners and two capped VHP-ready connections support wipe-down access and an optional validated biodecontamination package without building a sterilizer into every transfer box.
مخاوف المنتج للعملاء
Containment laboratories need a material route that limits direct room-to-room airflow, keeps contaminated chamber air within a filtered path and makes each door-release condition visible to operators.
تطبيقات نموذجية
المعلمات الفنية
Typical configurable construction values for the illustrated gas-tight negative-pressure biosafety transfer box are listed below.
| المواد الأساسية | All-welded AISI 316L stainless-steel inner chamber with AISI 304 service enclosure, colorless tempered-glass doors, charcoal EPDM seals and two separately gasketed HEPA stages |
|---|---|
| سمك اللوحة | 1.5 mm nominal AISI 316L inner-chamber panel |
| العرض الفعال | 610 mm nominal clear chamber width |
| الحد الأقصى الطول | Up to 610 mm nominal clear transfer depth in the selected configuration |
| الصلب يواجه سمك | 1.5 mm nominal AISI 304 external service facing |
| الكثافة الأساسية | 8000 kg/m³ for representative AISI 316L stainless-steel components |
| الموصلية الحرارية | 15 W/(m·K) for representative AISI 316L stainless steel at room temperature |
| إنهاء السطح | Neutral silver satin-brushed chamber and enclosure, colorless clear glazing, charcoal-black EPDM and handles, dark-blue screen, green and red status lenses |
| نوع المشترك | Two opposing gasket-compression glazed doors with a one-door-at-a-time electrical interlock, rear wall flange and a dual-HEPA negative-pressure purge circuit |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Biosafety Pass Box specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية