Isolator Pengisian Aseptik

A custom barrier enclosure integrated around filling, stoppering and closure equipment to protect open sterile containers throughout the critical process.
  • Filling-Line Integration
  • Critical-Zone Unidirectional Air
  • Glove-Assisted Intervention
  • Closed Component Transfer
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The aseptic filling isolator is designed around the exact fill-finish equipment rather than supplied as an empty cabinet. Chamber sections enclose container infeed, filling, stoppering and critical closure steps, with HEPA-filtered unidirectional air directed over open containers. Glove ports permit planned interventions, while rapid transfer ports, transfer hatches or sterile connectors introduce components. Removable or lift-up lower sections preserve access to the filling machine for controlled maintenance.

Ciri-ciri Utama

The chamber geometry follows the filling line and open-container path.

Dedicated diffuser zones maintain first air above critical filling and stoppering points.

Glove ports are positioned for defined interventions rather than general access.

Closed transfer interfaces introduce stoppers, tools and components.

Technical-side panels allow machine service without dismantling the complete barrier.

Kebimbangan Produk Pelanggan

The isolator must fit the filling machine while preserving first air, intervention reach and maintenance access along the complete container path.

Machine frames block clean air above open containers.Diffuser modules are divided around the actual fill and stopper positions.
Glove ports do not reach jam-clearance points.Intervention mapping sets glove locations before chamber fabrication.
Components enter through an open door during production.Rapid ports and sterile transfer interfaces feed closures and tools through closed paths.
Maintenance requires complete barrier removal.Sectioned technical panels and lift-up lower skirts expose the machine in a controlled shutdown.

Permohonan yang biasa

Vial filling and stopperingPrefilled syringe fillingCartridge fillingSmall-batch sterile fill-finish

Parameter teknikal

Typical configurable construction ranges for an aseptic filling isolator are listed below.

Bahan TerasWelded SUS316L barrier chamber with laminated safety glass and CSM glove assemblies around filling equipment
Ketebalan Panel50-120 mm chamber, plenum and service sections
Lebar berkesan1800-6000 mm protected line width
Panjang maksimumUp to 20000 mm integrated filling-line length
Keluli Menghadapi Ketebalan2.0-3.0 mm SUS316L chamber shell; 1.2-1.5 mm removable service skins
Ketumpatan terasApproximately 8000 kg/m³ for SUS316L chamber material
Kekonduksian Terma14-16 W / (m · K) untuk keluli tahan karat austenit
Kemasan permukaanElectropolished SUS316L interior with flush glazed panels and radiused transitions
Jenis BersatuWelded modular barrier sections with sealed machine interfaces, glove rings and rapid transfer ports
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Vial, syringe or cartridge line integrationIntegrated vapor bio-decontaminationRapid transfer and component portsGlove integrity and environmental monitoring connections

Planning a Aseptic Filling Isolator specification?