Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Kontrol Cleanroom dan Sistem Pemantauan Lingkungan / Temperature and Humidity Control System
Kontrol Cleanroom dan Sistem Pemantauan Lingkungan

Sistem kontrol suhu dan kelembaban

A precision environmental controller that coordinates room sensing, cooling, reheating, humidification and dehumidification without allowing the loops to oppose one another.
  • Coordinated Temperature and RH
  • High-Stability Room Sensing
  • Heating and Cooling Sequencing
  • Humidity Limit Protection
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The temperature and humidity control system uses stable room transmitters and sequenced HVAC outputs to maintain two strongly coupled variables. Cooling capacity can remove sensible and latent load, while reheating restores supply-air temperature after dehumidification. Humidifier commands are limited when duct or room conditions could create condensation. Separate occupied, setback and recovery modes allow the cleanroom to reach operating conditions predictably without excessive simultaneous heating and cooling.

Fitur utama:

Matched temperature and humidity sensing reduces drift between room display and control input.

Sequenced outputs prevent humidification and dehumidification from running against each other.

Dew-point and high-limit logic protects ductwork from unwanted moisture accumulation.

Trendable setpoints, outputs and alarms make slow environmental drift easier to diagnose.

Kekhawatiran produk pelanggan

Temperature and relative humidity interact through cooling, reheating and process moisture, so independent loops often waste energy or oscillate.

Cooling lowers temperature but leaves relative humidity unstable after reheating.A coordinated sequence manages cooling, reheat and moisture removal as one control strategy.
Room sensors drift and create disagreement between control and monitoring values.Stable matched transmitters with accessible calibration points keep the control reference consistent.
Humidifier output causes condensation in cooler duct sections.Dew-point and duct high-limit signals clamp humidifier demand before moisture deposits.
The room takes too long to recover after a production shutdown.A dedicated recovery mode applies controlled maximum outputs until both variables enter their operating bands.

Aplikasi yang Tipis

Pharmaceutical processing roomsMedical-device production roomsPrecision electronics productionControlled stability laboratories

Parameter teknis

Typical construction for a cleanroom temperature and humidity control panel with room transmitter is listed below.

Bahan intiPowder-coated steel control enclosure with FR-4 controller board and polymer room transmitter
Ketebalan Panel (Panel Thickness)160-300 mm enclosure depth
Efektif lebar400-800 mm panel width
Panjang maksimumUp to 1200 mm panel height
Baja menghadap ketebalan1.2-1.5 mm powder-coated steel enclosure
Kepadatan inti (core density)7800-8050 kg/m³ for steel panel components
Konduktivitas Termal (Thermal Conductivity)45-60 W/(m·K) for the steel enclosure
Permukaan selesaiFine-textured light-gray powder coat with white room sensor and color HMI
Jenis BersamaDIN-rail control panel with removable HVAC output terminals and network connection
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Cooling and reheat stagesSteam or ultrasonic humidifier outputDew-point high limitRemote room transmitter

Planning a Temperature and Humidity Control System specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami