Laman Utama / Produk / Sistem Kawalan Bilik Bersih dan Pemantauan Alam Sekitar / Temperature and Humidity Control System
Sistem Kawalan Bilik Bersih dan Pemantauan Alam Sekitar

Sistem Kawalan Suhu dan Kelembapan

A precision environmental controller that coordinates room sensing, cooling, reheating, humidification and dehumidification without allowing the loops to oppose one another.
  • Coordinated Temperature and RH
  • High-Stability Room Sensing
  • Heating and Cooling Sequencing
  • Humidity Limit Protection
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The temperature and humidity control system uses stable room transmitters and sequenced HVAC outputs to maintain two strongly coupled variables. Cooling capacity can remove sensible and latent load, while reheating restores supply-air temperature after dehumidification. Humidifier commands are limited when duct or room conditions could create condensation. Separate occupied, setback and recovery modes allow the cleanroom to reach operating conditions predictably without excessive simultaneous heating and cooling.

Ciri-ciri Utama

Matched temperature and humidity sensing reduces drift between room display and control input.

Sequenced outputs prevent humidification and dehumidification from running against each other.

Dew-point and high-limit logic protects ductwork from unwanted moisture accumulation.

Trendable setpoints, outputs and alarms make slow environmental drift easier to diagnose.

Kebimbangan Produk Pelanggan

Temperature and relative humidity interact through cooling, reheating and process moisture, so independent loops often waste energy or oscillate.

Cooling lowers temperature but leaves relative humidity unstable after reheating.A coordinated sequence manages cooling, reheat and moisture removal as one control strategy.
Room sensors drift and create disagreement between control and monitoring values.Stable matched transmitters with accessible calibration points keep the control reference consistent.
Humidifier output causes condensation in cooler duct sections.Dew-point and duct high-limit signals clamp humidifier demand before moisture deposits.
The room takes too long to recover after a production shutdown.A dedicated recovery mode applies controlled maximum outputs until both variables enter their operating bands.

Permohonan yang biasa

Pharmaceutical processing roomsMedical-device production roomsPrecision electronics productionControlled stability laboratories

Parameter teknikal

Typical construction for a cleanroom temperature and humidity control panel with room transmitter is listed below.

Bahan TerasPowder-coated steel control enclosure with FR-4 controller board and polymer room transmitter
Ketebalan Panel160-300 mm enclosure depth
Lebar berkesan400-800 mm panel width
Panjang maksimumUp to 1200 mm panel height
Keluli Menghadapi Ketebalan1.2-1.5 mm powder-coated steel enclosure
Ketumpatan teras7800-8050 kg/m³ for steel panel components
Kekonduksian Terma45-60 W/(m·K) for the steel enclosure
Kemasan permukaanFine-textured light-gray powder coat with white room sensor and color HMI
Jenis BersatuDIN-rail control panel with removable HVAC output terminals and network connection
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Cooling and reheat stagesSteam or ultrasonic humidifier outputDew-point high limitRemote room transmitter