Startseite / Produkte / Reinraumsteuerung und Umweltüberwachungssysteme / Temperature and Humidity Control System
Reinraumsteuerung und Umweltüberwachungssysteme

Temperatur - und Feuchtigkeitssteuerungssystem

A precision environmental controller that coordinates room sensing, cooling, reheating, humidification and dehumidification without allowing the loops to oppose one another.
  • Coordinated Temperature and RH
  • High-Stability Room Sensing
  • Heating and Cooling Sequencing
  • Humidity Limit Protection

Produkteinführung

The temperature and humidity control system uses stable room transmitters and sequenced HVAC outputs to maintain two strongly coupled variables. Cooling capacity can remove sensible and latent load, while reheating restores supply-air temperature after dehumidification. Humidifier commands are limited when duct or room conditions could create condensation. Separate occupied, setback and recovery modes allow the cleanroom to reach operating conditions predictably without excessive simultaneous heating and cooling.

Key Features

Matched temperature and humidity sensing reduces drift between room display and control input.

Sequenced outputs prevent humidification and dehumidification from running against each other.

Dew-point and high-limit logic protects ductwork from unwanted moisture accumulation.

Trendable setpoints, outputs and alarms make slow environmental drift easier to diagnose.

Kunden Produktbedenken

Temperature and relative humidity interact through cooling, reheating and process moisture, so independent loops often waste energy or oscillate.

Cooling lowers temperature but leaves relative humidity unstable after reheating.A coordinated sequence manages cooling, reheat and moisture removal as one control strategy.
Room sensors drift and create disagreement between control and monitoring values.Stable matched transmitters with accessible calibration points keep the control reference consistent.
Humidifier output causes condensation in cooler duct sections.Dew-point and duct high-limit signals clamp humidifier demand before moisture deposits.
The room takes too long to recover after a production shutdown.A dedicated recovery mode applies controlled maximum outputs until both variables enter their operating bands.

Typische Anwendungen

Pharmaceutical processing roomsProduktionsräume für medizinische GerätePrecision electronics productionControlled stability laboratories

Technische Parameter

Typical construction for a cleanroom temperature and humidity control panel with room transmitter is listed below.

Core MaterialPowder-coated steel control enclosure with FR-4 controller board and polymer room transmitter
Panel Dicke160-300 mm enclosure depth
Effektive Breite400-800 mm panel width
Maximale LängeUp to 1200 mm panel height
Stahl facing Dicke1.2-1.5 mm powder-coated steel enclosure
Kerndichte7800-8050 kg/m³ for steel panel components
Thermische Leitfähigkeit45-60 W/(m·K) for the steel enclosure
Oberfläche FinishFine-textured light-gray powder coat with white room sensor and color HMI
Gemeinsamer TypDIN-rail control panel with removable HVAC output terminals and network connection
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Cooling and reheat stagesSteam or ultrasonic humidifier outputDew-point high limitRemote room transmitter

Planning a Temperature and Humidity Control System specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.