클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

온도 및 습도 제어 시스템 Temperature and Humidity Control System

A precision environmental controller that coordinates room sensing, cooling, reheating, humidification and dehumidification without allowing the loops to oppose one another.
  • Coordinated Temperature and RH
  • High-Stability Room Sensing
  • Heating and Cooling Sequencing
  • Humidity Limit Protection
견적 요청 제품 찾아보기

상품 소개

The temperature and humidity control system uses stable room transmitters and sequenced HVAC outputs to maintain two strongly coupled variables. Cooling capacity can remove sensible and latent load, while reheating restores supply-air temperature after dehumidification. Humidifier commands are limited when duct or room conditions could create condensation. Separate occupied, setback and recovery modes allow the cleanroom to reach operating conditions predictably without excessive simultaneous heating and cooling.

주요 기능

Matched temperature and humidity sensing reduces drift between room display and control input.

Sequenced outputs prevent humidification and dehumidification from running against each other.

Dew-point and high-limit logic protects ductwork from unwanted moisture accumulation.

Trendable setpoints, outputs and alarms make slow environmental drift easier to diagnose.

고객 제품 관심사

Temperature and relative humidity interact through cooling, reheating and process moisture, so independent loops often waste energy or oscillate.

Cooling lowers temperature but leaves relative humidity unstable after reheating.A coordinated sequence manages cooling, reheat and moisture removal as one control strategy.
Room sensors drift and create disagreement between control and monitoring values.Stable matched transmitters with accessible calibration points keep the control reference consistent.
Humidifier output causes condensation in cooler duct sections.Dew-point and duct high-limit signals clamp humidifier demand before moisture deposits.
The room takes too long to recover after a production shutdown.A dedicated recovery mode applies controlled maximum outputs until both variables enter their operating bands.

일반적인 응용 프로그램

Pharmaceutical processing roomsMedical-device production roomsPrecision electronics productionControlled stability laboratories

기술 매개변수

Typical construction for a cleanroom temperature and humidity control panel with room transmitter is listed below.

핵심 재료Powder-coated steel control enclosure with FR-4 controller board and polymer room transmitter
패널 두께160-300 mm enclosure depth
유효 폭400-800 mm panel width
최대 길이Up to 1200 mm panel height
강철 면면 두께1.2-1.5 mm powder-coated steel enclosure
코어 밀도7800-8050 kg/m³ for steel panel components
열전도도 (Thermal Conductivity)45-60 W/(m·K) for the steel enclosure
표면 마무리Fine-textured light-gray powder coat with white room sensor and color HMI
접합 유형DIN-rail control panel with removable HVAC output terminals and network connection
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Cooling and reheat stagesSteam or ultrasonic humidifier outputDew-point high limitRemote room transmitter

Planning a Temperature and Humidity Control System specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기