Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Systèmes de contrôle des salles blanches et de surveillance environnementale

Z Système de contrôle de température et d'humidité par

A precision environmental controller that coordinates room sensing, cooling, reheating, humidification and dehumidification without allowing the loops to oppose one another.
  • Coordinated Temperature and RH
  • High-Stability Room Sensing
  • Heating and Cooling Sequencing
  • Humidity Limit Protection
Demander un devis. Browse les produits

Introduction de produit

The temperature and humidity control system uses stable room transmitters and sequenced HVAC outputs to maintain two strongly coupled variables. Cooling capacity can remove sensible and latent load, while reheating restores supply-air temperature after dehumidification. Humidifier commands are limited when duct or room conditions could create condensation. Separate occupied, setback and recovery modes allow the cleanroom to reach operating conditions predictably without excessive simultaneous heating and cooling.

Key Features

Matched temperature and humidity sensing reduces drift between room display and control input.

Sequenced outputs prevent humidification and dehumidification from running against each other.

Dew-point and high-limit logic protects ductwork from unwanted moisture accumulation.

Trendable setpoints, outputs and alarms make slow environmental drift easier to diagnose.

Préoccupations du client produit

Temperature and relative humidity interact through cooling, reheating and process moisture, so independent loops often waste energy or oscillate.

Cooling lowers temperature but leaves relative humidity unstable after reheating.A coordinated sequence manages cooling, reheat and moisture removal as one control strategy.
Room sensors drift and create disagreement between control and monitoring values.Stable matched transmitters with accessible calibration points keep the control reference consistent.
Humidifier output causes condensation in cooler duct sections.Dew-point and duct high-limit signals clamp humidifier demand before moisture deposits.
The room takes too long to recover after a production shutdown.A dedicated recovery mode applies controlled maximum outputs until both variables enter their operating bands.

Les applications typiques

Salles de traitement pharmaceutiqueMedical-device production roomsPrecision electronics productionControlled stability laboratories

Paramètres techniques

Typical construction for a cleanroom temperature and humidity control panel with room transmitter is listed below.

Matériaux de basePowder-coated steel control enclosure with FR-4 controller board and polymer room transmitter
Panneau épaisseur160-300 mm enclosure depth
Largeur effective400-800 mm panel width
Longueur maximaleUp to 1200 mm panel height
Acier face épaisseur1.2-1.5 mm powder-coated steel enclosure
Densité Core7800-8050 kg/m³ for steel panel components
Conductivité thermique45-60 W/(m·K) for the steel enclosure
surface finieFine-textured light-gray powder coat with white room sensor and color HMI
Type jointDIN-rail control panel with removable HVAC output terminals and network connection
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Cooling and reheat stagesSteam or ultrasonic humidifier outputDew-point high limitRemote room transmitter

Planning a Temperature and Humidity Control System specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe
Email nous WhatsApp WeChat