Personal und Material Dekontamination Ausrüstung
Automatische Schiebetür Cleanroom Air Dusche
A hands-free personnel air shower with powered sliding doors that coordinate opening, closing and the cleaning cycle through presence and safety sensors.
- Touch-Free Sliding Doors
- Presence Detection
- Anti-Pinch Protection
- Hands-Free Gowned Access
Produkteinführung
This air shower eliminates the need for gowned personnel to touch a door handle. A presence sensor opens the entry leaf, then door-closed and lock signals allow the airflow cycle to begin. After cleaning, the clean-side sliding door opens through the programmed sequence. Top-hung movement avoids the floor swing clearance and lower track contamination associated with conventional hinged doors.
Key Features
Sliding leaves preserve aisle space that would otherwise be used by door swing arcs.
Safety beams can stop or reverse the door if the clear opening is obstructed.
Closed-position feedback prevents the cleaning cycle from beginning too early.
Covered guides keep mechanical components away from the clean floor surface.
Kunden Produktbedenken
Automatic doors must reduce touch points without allowing a fan cycle to start before the opening is safely closed.
Gloved users repeatedly touch manual handles.Presence sensors and powered sliding leaves allow hands-free operation.
A moving door can meet a person or trolley in the opening.Anti-pinch sensing monitors the aperture and commands a stop or reversal when obstructed.
The fan may start before the leaf is sealed.Door-closed and lock feedback are both required before blower operation is enabled.
Floor tracks collect debris and complicate cleaning.A top-hung operator with a covered guide reduces exposed floor-level hardware.
Typische Anwendungen
Hands-free pharmaceutical gowningHospital sterile productionFood hygiene entrancesHigh-traffic electronics cleanrooms
Technische Parameter
Typical values for a sensor-operated sliding-door air shower are listed below.
| Core Material | Insulated steel or SUS 304 enclosure with H13 HEPA airflow circuit, powered door operators and stainless directional nozzles |
|---|---|
| Panel Dicke | 50 mm insulated wall and roof panels |
| Effektive Breite | 900-1400 mm clear automatic doorway width |
| Maximale Länge | Up to 3000 mm chamber and door-pocket length |
| Stahl facing Dicke | 1.0-1.2 mm body facing with reinforced operator support rail |
| Kerndichte | 40-50 kg/m³ rigid polyurethane or composite insulation |
| Thermische Leitfähigkeit | 0.024-0.031 W/(m·K) for the insulated enclosure panel |
| Oberfläche Finish | Smooth white powder coat or brushed stainless steel with covered door tracks |
| Gemeinsamer Typ | Flush gasketed enclosure seams with top-hung sliding leaves and monitored closing seals |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Single or bi-parting leavesMicrowave or infrared sensorCard-reader integrationEmergency door-release package
Planning a Automatic Sliding-Door Cleanroom Air Shower specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch
DeutschCurrent
Arabisch
Französisch
indonesisch
Japanisch
Koreanisch
Malaiisch
Portugiesisch
Russisch
Spanisch
Thailändisch
Türkischer Sprache
Vietnamesisch