موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
منتجات المراقبة البيئية الميكروبيولوجية

في الوقت الحقيقي عداد الجسيمات القابلة للحياة

A biofluorescent aerosol monitor that reports viable-like and total airborne particle signals continuously without waiting for culture incubation.
  • Laser-Induced Fluorescence
  • Simultaneous Total and Viable Signals
  • 28.3 L/min Continuous Sampling
  • Integrated Particle Collection
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The Real-Time Viable Particle Counter draws cleanroom air through one isokinetic inlet and measures individual aerosols in an optical chamber. A red sizing laser reports total-particle size while a violet excitation laser stimulates intrinsic fluorophores associated with biological material; multiple emission channels improve discrimination from non-biological interferents. Counts, trends and alarms appear immediately, and an optional downstream collection filter preserves sampled material for later identification. The stainless enclosure, internal pump and filtered exhaust support standalone surveys or continuous facility-monitoring integration.

الخصائص الرئيسية

Dual optical analysis provides simultaneous total-particle and biofluorescent counts from one sample stream.

Continuous electronic results reveal short contamination events that incubation-based spot samples may miss.

A 28.3 L/min closed-loop flow path supports representative Grade A continuous monitoring.

An integrated collection filter can retain aerosols for subsequent laboratory characterization.

مخاوف المنتج للعملاء

Biofluorescent monitoring provides immediate signals but requires controlled airflow, optical discrimination and a defined investigation strategy for detected events.

Traditional agar results arrive too late to identify the exact process event.Second-by-second fluorescence and particle trends correlate excursions with interventions and equipment activity.
Non-biological fluorescent material can create misleading viable-like counts.Multiple fluorescence channels and particle-sizing information improve discrimination and support site evaluation.
A real-time signal alone does not identify an organism.An in-line collection filter retains sampled material for appropriate downstream identification work.
Flow loss can appear as an artificially clean environment.Closed-loop flow monitoring creates an instrument alarm separate from environmental count limits.

تطبيقات نموذجية

Continuous Grade A viable monitoringAseptic process investigationsCleanroom room-release studiesGowning and intervention assessment

المعلمات الفنية

Typical materials and envelope values for a real-time biofluorescent particle counter are listed below.

المواد الأساسيةStainless steel enclosure with anodized aluminum optical bench and glass laser optics
سمك اللوحة250-320 mm enclosure depth
العرض الفعال250-300 mm cabinet width
الحد الأقصى الطولUp to 500 mm enclosure height excluding probe
الصلب يواجه سمك1.0-1.5 mm stainless enclosure panels
الكثافة الأساسية2650-8000 kg/m³ across aluminum optical frame and stainless enclosure
الموصلية الحرارية14-220 W/(m·K) across stainless steel and aluminum components
إنهاء السطحFine brushed stainless steel with black glass touchscreen and blue-green status indicators
نوع المشتركIsokinetic stainless inlet, internal HEPA-filtered exhaust, Ethernet/USB ports and dry-contact alarm terminals
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Multiple particle-size and fluorescence channelsIntegrated collection filterFacility-monitoring software interfaceEnvironmental sensor inputs

Planning a Real-Time Viable Particle Counter specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا