Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Sản phẩm giám sát môi trường vi sinh học

Bộ đếm hạt khả thi thời gian thực

A biofluorescent aerosol monitor that reports viable-like and total airborne particle signals continuously without waiting for culture incubation.
  • Laser-Induced Fluorescence
  • Simultaneous Total and Viable Signals
  • 28.3 L/min Continuous Sampling
  • Integrated Particle Collection
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

The Real-Time Viable Particle Counter draws cleanroom air through one isokinetic inlet and measures individual aerosols in an optical chamber. A red sizing laser reports total-particle size while a violet excitation laser stimulates intrinsic fluorophores associated with biological material; multiple emission channels improve discrimination from non-biological interferents. Counts, trends and alarms appear immediately, and an optional downstream collection filter preserves sampled material for later identification. The stainless enclosure, internal pump and filtered exhaust support standalone surveys or continuous facility-monitoring integration.

Các tính năng chính

Dual optical analysis provides simultaneous total-particle and biofluorescent counts from one sample stream.

Continuous electronic results reveal short contamination events that incubation-based spot samples may miss.

A 28.3 L/min closed-loop flow path supports representative Grade A continuous monitoring.

An integrated collection filter can retain aerosols for subsequent laboratory characterization.

Các mối quan tâm về sản phẩm của khách hàng

Biofluorescent monitoring provides immediate signals but requires controlled airflow, optical discrimination and a defined investigation strategy for detected events.

Traditional agar results arrive too late to identify the exact process event.Second-by-second fluorescence and particle trends correlate excursions with interventions and equipment activity.
Non-biological fluorescent material can create misleading viable-like counts.Multiple fluorescence channels and particle-sizing information improve discrimination and support site evaluation.
A real-time signal alone does not identify an organism.An in-line collection filter retains sampled material for appropriate downstream identification work.
Flow loss can appear as an artificially clean environment.Closed-loop flow monitoring creates an instrument alarm separate from environmental count limits.

Các ứng dụng điển hình

Continuous Grade A viable monitoringAseptic process investigationsCleanroom room-release studiesGowning and intervention assessment

Thông số kỹ thuật

Typical materials and envelope values for a real-time biofluorescent particle counter are listed below.

Vật liệu lõiStainless steel enclosure with anodized aluminum optical bench and glass laser optics
Độ dày bảng điều khiển250-320 mm enclosure depth
Chiều rộng hiệu quả250-300 mm cabinet width
Chiều dài tối đaUp to 500 mm enclosure height excluding probe
Thép đối mặt với độ dày1.0-1.5 mm stainless enclosure panels
Mật độ lõi2650-8000 kg/m³ across aluminum optical frame and stainless enclosure
Độ dẫn nhiệt14-220 W/(m·K) across stainless steel and aluminum components
Kết thúc bề mặtFine brushed stainless steel with black glass touchscreen and blue-green status indicators
Loại khớp nốiIsokinetic stainless inlet, internal HEPA-filtered exhaust, Ethernet/USB ports and dry-contact alarm terminals
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Multiple particle-size and fluorescence channelsIntegrated collection filterFacility-monitoring software interfaceEnvironmental sensor inputs

Planning a Real-Time Viable Particle Counter specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi