محلل نقاء النيتروجين
- Trace O₂-based nitrogen check.
- Percent N₂ and ppm O₂ display.
- Single controlled portable sample path.
مقدمة المنتج
This portable analyzer uses a dedicated trace-oxygen sensing path to evaluate nitrogen from generators, pipelines and storage points. Its tall protected enclosure combines one display, a five-key navigation cluster, one visible variable-area flowmeter and one fine-control valve without the multiple channels of a general gas-quality system. The primary screen can show calculated nitrogen purity while a smaller line retains the measured oxygen value in ppm. Because nitrogen purity is inferred from residual oxygen, the calculation is appropriate only when oxygen is the defined balance impurity; moisture, argon, carbon dioxide, hydrocarbons and other contaminants require separate measurements when they are relevant to the specification.
الخصائص الرئيسية
Dual presentation keeps the calculated percent-N₂ value and the actual residual-O₂ reading visible for clearer interpretation.
One slim flowmeter and one fine adjustment valve provide a simple, observable sample condition during purge and stabilization.
A short low-volume tube, stainless inlet and detachable quick coupling help limit ambient-air ingress when moving between sampling points.
Five-key interface separates navigation, confirmation and calibration functions while retaining a compact single-screen layout.
Tall portable housing, integrated handle, rear support and protected service cover suit temporary checks beside nitrogen generation and distribution equipment.
مخاوف المنتج للعملاء
High-purity nitrogen checks are especially sensitive to ambient-air leaks, permeable tubing, insufficient regulator purge and unstable sample flow; the meaning of a calculated N₂ value also depends on whether oxygen is truly the only balance impurity being assessed.
تطبيقات نموذجية
المعلمات الفنية
The construction below represents a portable nitrogen purity analyzer centered on trace-oxygen measurement. Measurement range, sensor chemistry, flow setting, pressure conditioning and wetted materials should be selected for the nitrogen source, expected residual-O₂ level and other gases present.
| المواد الأساسية | Impact-resistant PC/ABS enclosure with an anodized-aluminum internal carrier, 316L stainless-steel wetted inlet, PTFE sample tubing, borosilicate flow tube and a trace-oxygen sensor selected for the nitrogen matrix |
|---|---|
| سمك اللوحة | Typically 2.5-3.5 mm for the molded front panel and enclosure walls |
| العرض الفعال | Approximately 210-260 mm across the portrait-format portable enclosure |
| الحد الأقصى الطول | Approximately 320-390 mm over the complete enclosure, excluding the detachable sample tube |
| الصلب يواجه سمك | Typically 0.8-1.2 mm for internal stainless sensor brackets and electromagnetic shields |
| الكثافة الأساسية | Approximately 1080-1180 kg/m³ for the PC/ABS enclosure components |
| الموصلية الحرارية | Approximately 0.18-0.22 W/(m·K) for the PC/ABS enclosure components |
| إنهاء السطح | Deep-navy fine-texture outer shell, light-gray recessed instrument panel, cyan-white LCD, black controls, clear flow tube, satin stainless fittings and transparent or black low-permeation sample tubing |
| نوع المشترك | Single stainless sample inlet with detachable quick-coupled tube, panel-mounted fine-flow valve, one protected sensor-service cover and a rear folding support |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Nitrogen Purity Analyzer specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية