Máy phân tích độ tinh khiết nitơ
- Trace O₂-based nitrogen check.
- Percent N₂ and ppm O₂ display.
- Single controlled portable sample path.
Giới thiệu Sản phẩm
This portable analyzer uses a dedicated trace-oxygen sensing path to evaluate nitrogen from generators, pipelines and storage points. Its tall protected enclosure combines one display, a five-key navigation cluster, one visible variable-area flowmeter and one fine-control valve without the multiple channels of a general gas-quality system. The primary screen can show calculated nitrogen purity while a smaller line retains the measured oxygen value in ppm. Because nitrogen purity is inferred from residual oxygen, the calculation is appropriate only when oxygen is the defined balance impurity; moisture, argon, carbon dioxide, hydrocarbons and other contaminants require separate measurements when they are relevant to the specification.
Các tính năng chính
Dual presentation keeps the calculated percent-N₂ value and the actual residual-O₂ reading visible for clearer interpretation.
One slim flowmeter and one fine adjustment valve provide a simple, observable sample condition during purge and stabilization.
A short low-volume tube, stainless inlet and detachable quick coupling help limit ambient-air ingress when moving between sampling points.
Five-key interface separates navigation, confirmation and calibration functions while retaining a compact single-screen layout.
Tall portable housing, integrated handle, rear support and protected service cover suit temporary checks beside nitrogen generation and distribution equipment.
Các mối quan tâm về sản phẩm của khách hàng
High-purity nitrogen checks are especially sensitive to ambient-air leaks, permeable tubing, insufficient regulator purge and unstable sample flow; the meaning of a calculated N₂ value also depends on whether oxygen is truly the only balance impurity being assessed.
Các ứng dụng điển hình
Thông số kỹ thuật
The construction below represents a portable nitrogen purity analyzer centered on trace-oxygen measurement. Measurement range, sensor chemistry, flow setting, pressure conditioning and wetted materials should be selected for the nitrogen source, expected residual-O₂ level and other gases present.
| Vật liệu lõi | Impact-resistant PC/ABS enclosure with an anodized-aluminum internal carrier, 316L stainless-steel wetted inlet, PTFE sample tubing, borosilicate flow tube and a trace-oxygen sensor selected for the nitrogen matrix |
|---|---|
| Độ dày bảng điều khiển | Typically 2.5-3.5 mm for the molded front panel and enclosure walls |
| Chiều rộng hiệu quả | Approximately 210-260 mm across the portrait-format portable enclosure |
| Chiều dài tối đa | Approximately 320-390 mm over the complete enclosure, excluding the detachable sample tube |
| Thép đối mặt với độ dày | Typically 0.8-1.2 mm for internal stainless sensor brackets and electromagnetic shields |
| Mật độ lõi | Approximately 1080-1180 kg/m³ for the PC/ABS enclosure components |
| Độ dẫn nhiệt | Approximately 0.18-0.22 W/(m·K) for the PC/ABS enclosure components |
| Kết thúc bề mặt | Deep-navy fine-texture outer shell, light-gray recessed instrument panel, cyan-white LCD, black controls, clear flow tube, satin stainless fittings and transparent or black low-permeation sample tubing |
| Loại khớp nối | Single stainless sample inlet with detachable quick-coupled tube, panel-mounted fine-flow valve, one protected sensor-service cover and a rear folding support |
| Tùy chỉnh | Có sẵn dựa trên ứng dụng dự định và môi trường hoạt động. |
Các tùy chọn có sẵn
Planning a Nitrogen Purity Analyzer specification?
Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Tiếng Anh
Tiếng Đức, tiếng Đức
Tiếng Ả Rập, tiếng Ả Rập
Tiếng Pháp, tiếng Pháp
Tiếng Indonesia (tiếng Việt)
Tiếng Nhật
Tiếng Hàn / tiếng Hàn
Tiếng Mã Lai
Tiếng Bồ Đào Nha, tiếng Bồ Đào Nha
Tiếng Nga, tiếng Nga
Tiếng Tây Ban Nha, tiếng Tây Ban Nha
Tiếng Thái (tiếng Thái)
Tiếng Thổ Nhĩ Kỳ, tiếng Thổ Nhĩ Kỳ
Tiếng Việt / tiếng ViệtHiện tại