Analyseur d'azote pur
- Trace O₂-based nitrogen check.
- Percent N₂ and ppm O₂ display.
- Single controlled portable sample path.
Introduction de produit
This portable analyzer uses a dedicated trace-oxygen sensing path to evaluate nitrogen from generators, pipelines and storage points. Its tall protected enclosure combines one display, a five-key navigation cluster, one visible variable-area flowmeter and one fine-control valve without the multiple channels of a general gas-quality system. The primary screen can show calculated nitrogen purity while a smaller line retains the measured oxygen value in ppm. Because nitrogen purity is inferred from residual oxygen, the calculation is appropriate only when oxygen is the defined balance impurity; moisture, argon, carbon dioxide, hydrocarbons and other contaminants require separate measurements when they are relevant to the specification.
Key Features
Dual presentation keeps the calculated percent-N₂ value and the actual residual-O₂ reading visible for clearer interpretation.
One slim flowmeter and one fine adjustment valve provide a simple, observable sample condition during purge and stabilization.
A short low-volume tube, stainless inlet and detachable quick coupling help limit ambient-air ingress when moving between sampling points.
Five-key interface separates navigation, confirmation and calibration functions while retaining a compact single-screen layout.
Tall portable housing, integrated handle, rear support and protected service cover suit temporary checks beside nitrogen generation and distribution equipment.
Préoccupations du client produit
High-purity nitrogen checks are especially sensitive to ambient-air leaks, permeable tubing, insufficient regulator purge and unstable sample flow; the meaning of a calculated N₂ value also depends on whether oxygen is truly the only balance impurity being assessed.
Les applications typiques
Paramètres techniques
The construction below represents a portable nitrogen purity analyzer centered on trace-oxygen measurement. Measurement range, sensor chemistry, flow setting, pressure conditioning and wetted materials should be selected for the nitrogen source, expected residual-O₂ level and other gases present.
| Matériaux de base | Impact-resistant PC/ABS enclosure with an anodized-aluminum internal carrier, 316L stainless-steel wetted inlet, PTFE sample tubing, borosilicate flow tube and a trace-oxygen sensor selected for the nitrogen matrix |
|---|---|
| Panneau épaisseur | Typically 2.5-3.5 mm for the molded front panel and enclosure walls |
| Largeur effective | Approximately 210-260 mm across the portrait-format portable enclosure |
| Longueur maximale | Approximately 320-390 mm over the complete enclosure, excluding the detachable sample tube |
| Acier face épaisseur | Typically 0.8-1.2 mm for internal stainless sensor brackets and electromagnetic shields |
| Densité Core | Approximately 1080-1180 kg/m³ for the PC/ABS enclosure components |
| Conductivité thermique | Approximately 0.18-0.22 W/(m·K) for the PC/ABS enclosure components |
| surface finie | Deep-navy fine-texture outer shell, light-gray recessed instrument panel, cyan-white LCD, black controls, clear flow tube, satin stainless fittings and transparent or black low-permeation sample tubing |
| Type joint | Single stainless sample inlet with detachable quick-coupled tube, panel-mounted fine-flow valve, one protected sensor-service cover and a rear folding support |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Nitrogen Purity Analyzer specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien