Class الثالث مجلس الوزراء السلامة البيولوجية
- Gas-Tight Negative-Pressure Enclosure
- Four Fixed Gauntlet Ports
- Single-HEPA Supply and Double-HEPA Exhaust
- Interlocked Material Pass-Through
مقدمة المنتج
The Class III Biosafety Cabinet is a completely enclosed, ventilated glove-operated workstation for laboratory processes that require a physical barrier around the manipulation zone. Unlike an open-front Class II cabinet, the selected four-port configuration has one fixed sealed observation window and four mechanically attached neoprene gauntlets, so routine hand access does not create an open working aperture. Room air enters through one dedicated HEPA stage, while cabinet air leaves through two HEPA stages in series and a hard-duct exhaust collar; the connected exhaust system is selected to keep the work enclosure below the surrounding room pressure. A double-ended side pass-through uses a one-door-at-a-time interlock to move closed materials without opening the main chamber. The satin AISI 304 work zone is contained within a white powder-coated steel shell and supported on a mobile leveling stand. A local display, differential-pressure gauge and separate green-red status indicators make operating and alarm conditions visible. Final pressure, exhaust capacity, filter arrangement, transfer method and facility connection are configured for the site's risk assessment rather than inferred from the cabinet name alone.
الخصائص الرئيسية
One filtered supply path and two serial exhaust filter stages are paired with a dedicated duct collar so the facility exhaust can maintain inward leakage and negative cabinet pressure.
The integral double-ended transfer chamber uses opposing gasketed doors and a one-door-at-a-time interlock; it is a containment transfer route, not an autoclave or automatic sterilizer.
A local pressure gauge, control display and separate normal-alarm indicators provide direct feedback without opening the cabinet or relying only on a remote building interface.
مخاوف المنتج للعملاء
A Class III cabinet must keep the work zone physically closed, maintain a reliable filtered pressure path and provide a material route that does not bypass the containment boundary.
تطبيقات نموذجية
المعلمات الفنية
Representative configurable construction values for the illustrated four-gauntlet, negative-pressure Class III cabinet are listed below.
| المواد الأساسية | Fully welded gas-tight AISI 304 stainless-steel work enclosure with a white powder-coated electro-galvanized external shell, fixed safety glazing, neoprene gauntlets and gasketed HEPA housings |
|---|---|
| سمك اللوحة | 1.2 mm nominal AISI 304 work-zone panel |
| العرض الفعال | 1430 mm nominal internal work-zone width for the selected four-port configuration |
| الحد الأقصى الطول | Up to 1995 mm nominal overall equipment length including the integral side pass-through in the selected configuration |
| الصلب يواجه سمك | 1.5 mm nominal powder-coated steel external facing |
| الكثافة الأساسية | 7900 kg/m³ for representative AISI 304 stainless-steel components |
| الموصلية الحرارية | 15 W/(m·K) for representative AISI 304 stainless steel at room temperature |
| إنهاء السطح | White powder-coated exterior, neutral silver satin AISI 304 work zone, colorless clear glazing, charcoal-black gauntlets and seals, dark-blue display, green and red status lenses |
| نوع المشترك | Fully welded gas-tight enclosure with a fixed sealed viewing panel, four mechanically clamped gauntlet ports, an interlocked double-ended pass-through and a hard-connected single-supply/double-exhaust HEPA path |
| التخصيص | متوفر على أساس التطبيق المقصود وبيئة التشغيل. |
الخيارات المتاحة
Planning a Class III Biosafety Cabinet specification?
أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

English
الألمانية
العربيةالحالي
الفرنسية
الإندونيسية
اليابانية
الكورية
اللغة الملاوية
البرتغالية
الروسية
الإسبانية
التايلاندية
اللغة التركية
اللغة الفيتنامية