Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Drenajı, Hijyen ve Güvenlik Ekipmanları

Aspirasyon duman algılama sistemi

An active air-sampling detector that draws room air through a pipe network for sensitive, centralized smoke analysis.
  • Active Air Sampling
  • Multi-Level Early Warning
  • Supervised Pipe Network
  • Serviceable Central Detector
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The aspirating smoke detection system uses a monitored fan to draw air from distributed sampling holes through small-bore pipes into a filtered optical sensing chamber. Multiple alarm thresholds can distinguish developing conditions from established fire signatures, while airflow supervision reports blocked or broken sampling lines. Locating the detector cabinet in a serviceable position allows filter and chamber maintenance without opening every cleanroom ceiling point.

Ana Özellikler

Active sampling transports air from high-airflow zones to one calibrated detector.

Configurable thresholds support staged investigation and alarm response.

Airflow monitoring detects pipe blockage, leakage or fan faults.

Replaceable filters protect the optical chamber from background contamination.

Müşteri Ürün Sorunları

Dilution and directional airflow can delay passive detection, while cleanroom access makes frequent ceiling-device maintenance undesirable.

High air-change rates move smoke away from passive ceiling detectors.A distributed sampling network actively transports room air to the sensing chamber.
Very low alarm thresholds can react to harmless background particles.Filtration, reference settings and staged thresholds separate background from developing smoke.
A blocked sampling hole silently reduces coverage.Continuous airflow supervision reports deviation from the commissioned pipe baseline.
Servicing many room detectors disrupts controlled operations.The fan, filter and chamber are centralized in one accessible cabinet.

Tipik uygulamalar

Semiconductor cleanroomsPharmaceutical production suitesData and control roomsHigh-bay controlled spaces

Teknik parametreler

Typical cabinet construction and sampling-network envelope values are listed below; hole sizing and alarm thresholds are engineered for the airflow model.

Temel malzemelerPowder-coated steel cabinet with polymer sampling pipe and optical sensing electronics
Panel kalınlığı1.0-1.5 mm cabinet panels
Effective Width (Etkili Genişlik)250-500 mm cabinet width
Maksimum uzunlukUp to 1000 mm cabinet height
Çelik yüz yüze kalınlığı1.0-1.5 mm powder-coated steel enclosure
Core Density (Çekirdek Yoğunluğu)7850 kg/m³ for steel cabinet parts
Termal İletkenlik45-60 W/(m·K) for steel enclosure components
Yüzey bitirmeSmooth light-gray powder coating with status display
Ortak tipGasketed cabinet with supervised push-fit sampling-pipe connections
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Single or multi-pipe detectorRemote displayNetwork communication moduleCleanroom capillary sampling points

Planning a Aspirating Smoke Detection System specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim