Sistem Pengesanan Asap Beraspirasi

An active air-sampling detector that draws room air through a pipe network for sensitive, centralized smoke analysis.
  • Active Air Sampling
  • Multi-Level Early Warning
  • Supervised Pipe Network
  • Serviceable Central Detector
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The aspirating smoke detection system uses a monitored fan to draw air from distributed sampling holes through small-bore pipes into a filtered optical sensing chamber. Multiple alarm thresholds can distinguish developing conditions from established fire signatures, while airflow supervision reports blocked or broken sampling lines. Locating the detector cabinet in a serviceable position allows filter and chamber maintenance without opening every cleanroom ceiling point.

Ciri-ciri Utama

Active sampling transports air from high-airflow zones to one calibrated detector.

Configurable thresholds support staged investigation and alarm response.

Airflow monitoring detects pipe blockage, leakage or fan faults.

Replaceable filters protect the optical chamber from background contamination.

Kebimbangan Produk Pelanggan

Dilution and directional airflow can delay passive detection, while cleanroom access makes frequent ceiling-device maintenance undesirable.

High air-change rates move smoke away from passive ceiling detectors.A distributed sampling network actively transports room air to the sensing chamber.
Very low alarm thresholds can react to harmless background particles.Filtration, reference settings and staged thresholds separate background from developing smoke.
A blocked sampling hole silently reduces coverage.Continuous airflow supervision reports deviation from the commissioned pipe baseline.
Servicing many room detectors disrupts controlled operations.The fan, filter and chamber are centralized in one accessible cabinet.

Permohonan yang biasa

Semiconductor cleanroomsPharmaceutical production suitesData and control roomsHigh-bay controlled spaces

Parameter teknikal

Typical cabinet construction and sampling-network envelope values are listed below; hole sizing and alarm thresholds are engineered for the airflow model.

Bahan TerasPowder-coated steel cabinet with polymer sampling pipe and optical sensing electronics
Ketebalan Panel1.0-1.5 mm cabinet panels
Lebar berkesan250-500 mm cabinet width
Panjang maksimumUp to 1000 mm cabinet height
Keluli Menghadapi Ketebalan1.0-1.5 mm powder-coated steel enclosure
Ketumpatan teras7850 kg/m³ for steel cabinet parts
Kekonduksian Terma45-60 W/(m·K) for steel enclosure components
Kemasan permukaanSmooth light-gray powder coating with status display
Jenis BersatuGasketed cabinet with supervised push-fit sampling-pipe connections
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Single or multi-pipe detectorRemote displayNetwork communication moduleCleanroom capillary sampling points

Planning a Aspirating Smoke Detection System specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.