Unidad de manejo de aire vertical

A stacked upflow or downflow air handler that reduces plant-room footprint while retaining full filter, coil and fan functionality.
  • Small Floor Footprint
  • Upflow or Downflow Layout
  • Stacked Service Sections
  • Rigid Vertical Frame
Solicite un presupuesto. Browse productos

Introducción del producto

The vertical air handling unit stacks treatment components to use room height instead of long floor area. Air may enter low and discharge upward, or follow a downflow path to a raised floor or low duct. Filters, coils and fan sections are separated by accessible service zones, and the frame is reinforced for the vertical component load. Drain and trap geometry are arranged for the selected casing pressure, while lifting points and removable panels support installation in compact plant rooms.

Características clave

Stacked treatment sections reduce the equipment footprint in narrow mechanical rooms.

Upflow and downflow discharge options align with high-level or underfloor duct systems.

Reinforced base and frame transfer fan, coil and filter loads through the vertical casing.

Dedicated access doors keep filter and wet-section service points reachable from one side.

Preocupaciones del producto del cliente

Stacking components saves floor space only if service access, drainage and structural loads are addressed in the vertical arrangement.

A horizontal unit blocks the only service aisle in a small plant room.Vertical stacking shortens the footprint while preserving treatment functions.
The discharge duct must turn sharply and adds unnecessary pressure loss.Upflow or downflow discharge connects directly to the building riser or floor plenum.
Upper filters are difficult to lift and remove safely.Filter stages are positioned at practical service height with slide-out tracks.
Condensate trap height is insufficient under negative casing pressure.The base frame provides clearance for a trap sized to the actual section pressure.

Aplicaciones típicas

Compact cleanroom plant roomsHospital mechanical closetsLaboratory retrofit shaftsVertical supply risersUnderfloor clean-air systems

Parámetros técnicos

Typical casing values for an insulated vertical air handling unit are listed below.

Materiales CorePolyurethane or mineral-wool insulation in reinforced double-skin panels
Panel de espesor40–60 mm insulated panel
Ancho efectivo800–2400 mm nominal casing width
Longitud máximaUp to 3500 mm horizontal base length for stacked configuration
Acero frente a espesor0.6–1.0 mm casing skins with reinforced base members
Densidad Core41–45 kg/m³ polyurethane or 84–100 kg/m³ mineral wool
Conductividad térmica0.022–0.040 W/(m·K) according to panel core
Superficie acabadaPowder-coated galvanized exterior with galvanized or stainless inner lining
Tipo conjuntoCompression-gasketed stacked panels on bolted structural base and vertical frame
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Upflow, downflow or side dischargeChilled-water, hot-water or DX coilsEC plug fan or fan arrayBottom or side return-air connection