垂直空気取扱ユニット

A stacked upflow or downflow air handler that reduces plant-room footprint while retaining full filter, coil and fan functionality.
  • Small Floor Footprint
  • Upflow or Downflow Layout
  • Stacked Service Sections
  • Rigid Vertical Frame
見積もりリクエスト 製品案内

商品紹介

The vertical air handling unit stacks treatment components to use room height instead of long floor area. Air may enter low and discharge upward, or follow a downflow path to a raised floor or low duct. Filters, coils and fan sections are separated by accessible service zones, and the frame is reinforced for the vertical component load. Drain and trap geometry are arranged for the selected casing pressure, while lifting points and removable panels support installation in compact plant rooms.

主要な特徴

Stacked treatment sections reduce the equipment footprint in narrow mechanical rooms.

Upflow and downflow discharge options align with high-level or underfloor duct systems.

Reinforced base and frame transfer fan, coil and filter loads through the vertical casing.

Dedicated access doors keep filter and wet-section service points reachable from one side.

お客様の製品に関する懸念事項

Stacking components saves floor space only if service access, drainage and structural loads are addressed in the vertical arrangement.

A horizontal unit blocks the only service aisle in a small plant room.Vertical stacking shortens the footprint while preserving treatment functions.
The discharge duct must turn sharply and adds unnecessary pressure loss.Upflow or downflow discharge connects directly to the building riser or floor plenum.
Upper filters are difficult to lift and remove safely.Filter stages are positioned at practical service height with slide-out tracks.
Condensate trap height is insufficient under negative casing pressure.The base frame provides clearance for a trap sized to the actual section pressure.

典型的な用途

Compact cleanroom plant roomsHospital mechanical closetsLaboratory retrofit shaftsVertical supply risersUnderfloor clean-air systems

技術的なパラメータ

Typical casing values for an insulated vertical air handling unit are listed below.

コア材料Polyurethane or mineral-wool insulation in reinforced double-skin panels
パネルの厚さ40–60 mm insulated panel
有効幅800–2400 mm nominal casing width
最大長さUp to 3500 mm horizontal base length for stacked configuration
鋼鉄の厚さを直面する0.6–1.0 mm casing skins with reinforced base members
コア密度41–45 kg/m³ polyurethane or 84–100 kg/m³ mineral wool
熱伝導率0.022–0.040 W/(m·K) according to panel core
表面仕上げPowder-coated galvanized exterior with galvanized or stainless inner lining
ジョイントタイプCompression-gasketed stacked panels on bolted structural base and vertical frame
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Upflow, downflow or side dischargeChilled-water, hot-water or DX coilsEC plug fan or fan arrayBottom or side return-air connection