클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
/ 제품 / 클린룸 HVAC 및 공기 처리 장비 / Vertical Air Handling Unit
클린룸 HVAC 및 공기 처리 장비

수직 공기 처리 장치 Vertical Air Handling Unit

A stacked upflow or downflow air handler that reduces plant-room footprint while retaining full filter, coil and fan functionality.
  • Small Floor Footprint
  • Upflow or Downflow Layout
  • Stacked Service Sections
  • Rigid Vertical Frame
견적 요청 제품 찾아보기

상품 소개

The vertical air handling unit stacks treatment components to use room height instead of long floor area. Air may enter low and discharge upward, or follow a downflow path to a raised floor or low duct. Filters, coils and fan sections are separated by accessible service zones, and the frame is reinforced for the vertical component load. Drain and trap geometry are arranged for the selected casing pressure, while lifting points and removable panels support installation in compact plant rooms.

주요 기능

Stacked treatment sections reduce the equipment footprint in narrow mechanical rooms.

Upflow and downflow discharge options align with high-level or underfloor duct systems.

Reinforced base and frame transfer fan, coil and filter loads through the vertical casing.

Dedicated access doors keep filter and wet-section service points reachable from one side.

고객 제품 관심사

Stacking components saves floor space only if service access, drainage and structural loads are addressed in the vertical arrangement.

A horizontal unit blocks the only service aisle in a small plant room.Vertical stacking shortens the footprint while preserving treatment functions.
The discharge duct must turn sharply and adds unnecessary pressure loss.Upflow or downflow discharge connects directly to the building riser or floor plenum.
Upper filters are difficult to lift and remove safely.Filter stages are positioned at practical service height with slide-out tracks.
Condensate trap height is insufficient under negative casing pressure.The base frame provides clearance for a trap sized to the actual section pressure.

일반적인 응용 프로그램

Compact cleanroom plant roomsHospital mechanical closetsLaboratory retrofit shaftsVertical supply risersUnderfloor clean-air systems

기술 매개변수

Typical casing values for an insulated vertical air handling unit are listed below.

핵심 재료Polyurethane or mineral-wool insulation in reinforced double-skin panels
패널 두께40–60 mm insulated panel
유효 폭800–2400 mm nominal casing width
최대 길이Up to 3500 mm horizontal base length for stacked configuration
강철 면면 두께0.6–1.0 mm casing skins with reinforced base members
코어 밀도41–45 kg/m³ polyurethane or 84–100 kg/m³ mineral wool
열전도도 (Thermal Conductivity)0.022–0.040 W/(m·K) according to panel core
표면 마무리Powder-coated galvanized exterior with galvanized or stainless inner lining
접합 유형Compression-gasketed stacked panels on bolted structural base and vertical frame
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Upflow, downflow or side dischargeChilled-water, hot-water or DX coilsEC plug fan or fan arrayBottom or side return-air connection

Planning a Vertical Air Handling Unit specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기