Sistema de monitoreo de partículas multicanal
- One counter polls multiple identified sampling points.
- Programmable purge and sample steps sequence each line.
- Point identities stay linked to monitoring software.
Introducción del producto
This multi-channel particle monitoring system combines a precision valve manifold, clean sampling paths, sequence controller and compatible airborne particle counter. It automatically selects one location at a time, purges the active line and records the result against the correct point identifier. The architecture is intended for periodic trending across many locations where simultaneous continuous measurement is not required, reducing instrument count without losing a structured sampling plan.
Características clave
Programmable point order, purge duration and sample time create repeatable unattended monitoring cycles.
Bi-directional control allows the manifold and monitoring software to coordinate point status and timing.
Low-shedding internal flow paths minimize contamination contribution from the switching assembly.
Individual port identification keeps every particle result associated with the correct cleanroom location.
Modular tubing and communication options simplify phased expansion of the monitoring network.
Preocupaciones del producto del cliente
Sequential monitoring must clear residue from long lines, preserve the identity of each location, and balance purge plus sample time against the required polling cycle.
Aplicaciones típicas
Parámetros técnicos
The table defines representative cabinet, port, flow-path, and communication configurations for a multiport switching manifold, with selection based on point count, tubing layout, and particle-counter architecture.
| Materiales Core | Powder-coated steel or stainless-steel enclosure with chemically resistant internal valve manifold and clean sampling tubing |
|---|---|
| Panel de espesor | Typically 1.0–1.5 mm enclosure panel thickness |
| Ancho efectivo | Approximately 430–600 mm according to port count and rack configuration |
| Longitud máxima | Approximately 450–800 mm for the manifold enclosure; sampling runs may extend to 38100 mm when validated |
| Acero frente a espesor | Typically 1.0–1.5 mm powder-coated or stainless steel |
| Densidad Core | Not applicable; the equipment enclosure has no insulation core (0 kg/m³) |
| Conductividad térmica | Approximately 14–16 W/(m·K) for stainless steel or 45–60 W/(m·K) for carbon-steel enclosure sections |
| Superficie acabada | Smooth light-gray powder coating or fine-brushed stainless steel with labeled stainless tube ports |
| Tipo conjunto | Numbered compression-tube sampling ports with Ethernet or serial control interface |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Multi-Channel Particle Monitoring System specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita