Système de surveillance des particules multicanal
- One counter polls multiple identified sampling points.
- Programmable purge and sample steps sequence each line.
- Point identities stay linked to monitoring software.
Introduction de produit
This multi-channel particle monitoring system combines a precision valve manifold, clean sampling paths, sequence controller and compatible airborne particle counter. It automatically selects one location at a time, purges the active line and records the result against the correct point identifier. The architecture is intended for periodic trending across many locations where simultaneous continuous measurement is not required, reducing instrument count without losing a structured sampling plan.
Key Features
Programmable point order, purge duration and sample time create repeatable unattended monitoring cycles.
Bi-directional control allows the manifold and monitoring software to coordinate point status and timing.
Low-shedding internal flow paths minimize contamination contribution from the switching assembly.
Individual port identification keeps every particle result associated with the correct cleanroom location.
Modular tubing and communication options simplify phased expansion of the monitoring network.
Préoccupations du client produit
Sequential monitoring must clear residue from long lines, preserve the identity of each location, and balance purge plus sample time against the required polling cycle.
Les applications typiques
Paramètres techniques
The table defines representative cabinet, port, flow-path, and communication configurations for a multiport switching manifold, with selection based on point count, tubing layout, and particle-counter architecture.
| Matériaux de base | Powder-coated steel or stainless-steel enclosure with chemically resistant internal valve manifold and clean sampling tubing |
|---|---|
| Panneau épaisseur | Typically 1.0–1.5 mm enclosure panel thickness |
| Largeur effective | Approximately 430–600 mm according to port count and rack configuration |
| Longueur maximale | Approximately 450–800 mm for the manifold enclosure; sampling runs may extend to 38100 mm when validated |
| Acier face épaisseur | Typically 1.0–1.5 mm powder-coated or stainless steel |
| Densité Core | Not applicable; the equipment enclosure has no insulation core (0 kg/m³) |
| Conductivité thermique | Approximately 14–16 W/(m·K) for stainless steel or 45–60 W/(m·K) for carbon-steel enclosure sections |
| surface finie | Smooth light-gray powder coating or fine-brushed stainless steel with labeled stainless tube ports |
| Type joint | Numbered compression-tube sampling ports with Ethernet or serial control interface |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Multi-Channel Particle Monitoring System specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien