Mehrkanal-Partikel - Überwachungssystem
- One counter polls multiple identified sampling points.
- Programmable purge and sample steps sequence each line.
- Point identities stay linked to monitoring software.
Produkteinführung
This multi-channel particle monitoring system combines a precision valve manifold, clean sampling paths, sequence controller and compatible airborne particle counter. It automatically selects one location at a time, purges the active line and records the result against the correct point identifier. The architecture is intended for periodic trending across many locations where simultaneous continuous measurement is not required, reducing instrument count without losing a structured sampling plan.
Key Features
Programmable point order, purge duration and sample time create repeatable unattended monitoring cycles.
Bi-directional control allows the manifold and monitoring software to coordinate point status and timing.
Low-shedding internal flow paths minimize contamination contribution from the switching assembly.
Individual port identification keeps every particle result associated with the correct cleanroom location.
Modular tubing and communication options simplify phased expansion of the monitoring network.
Kunden Produktbedenken
Sequential monitoring must clear residue from long lines, preserve the identity of each location, and balance purge plus sample time against the required polling cycle.
Typische Anwendungen
Technische Parameter
The table defines representative cabinet, port, flow-path, and communication configurations for a multiport switching manifold, with selection based on point count, tubing layout, and particle-counter architecture.
| Core Material | Powder-coated steel or stainless-steel enclosure with chemically resistant internal valve manifold and clean sampling tubing |
|---|---|
| Panel Dicke | Typically 1.0–1.5 mm enclosure panel thickness |
| Effektive Breite | Approximately 430–600 mm according to port count and rack configuration |
| Maximale Länge | Approximately 450–800 mm for the manifold enclosure; sampling runs may extend to 38100 mm when validated |
| Stahl facing Dicke | Typically 1.0–1.5 mm powder-coated or stainless steel |
| Kerndichte | Not applicable; the equipment enclosure has no insulation core (0 kg/m³) |
| Thermische Leitfähigkeit | Approximately 14–16 W/(m·K) for stainless steel or 45–60 W/(m·K) for carbon-steel enclosure sections |
| Oberfläche Finish | Smooth light-gray powder coating or fine-brushed stainless steel with labeled stainless tube ports |
| Gemeinsamer Typ | Numbered compression-tube sampling ports with Ethernet or serial control interface |
| Customisierung | Verfügbar je nach beabsichtigter Anwendung und Betriebsumgebung. |
Verfügbare Optionen
Planning a Multi-Channel Particle Monitoring System specification?
Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Englisch