Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de HVAC y manejo de aire para salas limpias

Recalentamiento de agua caliente por

A shallow one- or two-row hydronic coil that restores neutral supply-air temperature after deep cooling and dehumidification.
  • Post-Dehumidification Reheat
  • Shallow Low-Pressure-Drop Face
  • Fast Valve Response
  • Compact AHU Integration
Solicite un presupuesto. Browse productos

Introducción del producto

The reheat coil is positioned downstream of a cooling coil so it can add sensible heat without increasing air moisture. Its shallow copper-tube and aluminum-fin construction minimizes air pressure drop while providing enough surface area for precise leaving-temperature control. Low water volume and short circuits respond quickly to a modulating valve, making the coil suitable for tight cleanroom temperature and humidity sequences.

Características clave

One- or two-row construction limits fan energy while delivering controlled sensible reheat.

Small internal water volume responds rapidly when the modulating valve changes position.

Accessible vents and drains prevent air binding during low-flow operation.

Compact casing fits between cooling-coil, fan and final-filter sections in constrained AHUs.

Preocupaciones del producto del cliente

Reheat must correct overcooled supply air precisely without adding excessive pressure drop or fighting the cooling sequence.

Air leaves the dehumidifying coil too cold for the occupied zone.A downstream hydronic coil adds only sensible heat and preserves the achieved moisture content.
An oversized multi-row coil causes sluggish temperature control.A shallow low-volume circuit responds quickly to modulating water flow.
Excessive fin resistance increases cleanroom fan power.A one- or two-row face and appropriate fin pitch minimize air-side pressure drop.
Simultaneous cooling and reheat waste plant energy.Heat-recovery or low-temperature return water can supply the reheat duty when available.

Aplicaciones típicas

Cleanroom temperature-humidity decouplingLaboratory dehumidification reheatHospital operating-room AHUsPharmaceutical make-up air unitsNeutral-temperature supply-air systems

Parámetros técnicos

Typical physical ranges for a compact AHU hot-water reheat coil are summarized below.

Materiales CoreCopper tubes with aluminum fins and compact copper headers
Panel de espesor1.2-1.8 mm galvanized steel casing
Ancho efectivo250-2200 mm active fin face width
Longitud máximaUp to 3200 mm overall casing length
Acero frente a espesor1.2-1.8 mm galvanized or stainless frame
Densidad CoreApproximately 2730 kg/m³ for the thin 3003 aluminum fin stock in the shallow reheat section
Conductividad térmicaApproximately 193 W/(m·K) for the 3003 aluminum reheat fins at room temperature
Superficie acabadaNatural or coated aluminum fins with bright galvanized casing
Tipo conjuntoBrazed copper tube/header joints inside a shallow flanged casing
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

One- or two-row circuitHeat-recovery, boiler-water or heat-pump-water serviceDifferent fin pitch and protective coatingsStainless casing with vent, drain and sensor pocket

Planning a Hot-Water Reheat Coil specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.