クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム HVAC および空気処理装置

Hot—Water 再熱コイル

A shallow one- or two-row hydronic coil that restores neutral supply-air temperature after deep cooling and dehumidification.
  • Post-Dehumidification Reheat
  • Shallow Low-Pressure-Drop Face
  • Fast Valve Response
  • Compact AHU Integration
見積もりリクエスト 製品案内

商品紹介

The reheat coil is positioned downstream of a cooling coil so it can add sensible heat without increasing air moisture. Its shallow copper-tube and aluminum-fin construction minimizes air pressure drop while providing enough surface area for precise leaving-temperature control. Low water volume and short circuits respond quickly to a modulating valve, making the coil suitable for tight cleanroom temperature and humidity sequences.

主要な特徴

One- or two-row construction limits fan energy while delivering controlled sensible reheat.

Small internal water volume responds rapidly when the modulating valve changes position.

Accessible vents and drains prevent air binding during low-flow operation.

Compact casing fits between cooling-coil, fan and final-filter sections in constrained AHUs.

お客様の製品に関する懸念事項

Reheat must correct overcooled supply air precisely without adding excessive pressure drop or fighting the cooling sequence.

Air leaves the dehumidifying coil too cold for the occupied zone.A downstream hydronic coil adds only sensible heat and preserves the achieved moisture content.
An oversized multi-row coil causes sluggish temperature control.A shallow low-volume circuit responds quickly to modulating water flow.
Excessive fin resistance increases cleanroom fan power.A one- or two-row face and appropriate fin pitch minimize air-side pressure drop.
Simultaneous cooling and reheat waste plant energy.Heat-recovery or low-temperature return water can supply the reheat duty when available.

典型的な用途

Cleanroom temperature-humidity decouplingLaboratory dehumidification reheatHospital operating-room AHUsPharmaceutical make-up air unitsNeutral-temperature supply-air systems

技術的なパラメータ

Typical physical ranges for a compact AHU hot-water reheat coil are summarized below.

コア材料Copper tubes with aluminum fins and compact copper headers
パネルの厚さ1.2-1.8 mm galvanized steel casing
有効幅250-2200 mm active fin face width
最大長さUp to 3200 mm overall casing length
鋼鉄の厚さを直面する1.2-1.8 mm galvanized or stainless frame
コア密度Approximately 2730 kg/m³ for the thin 3003 aluminum fin stock in the shallow reheat section
熱伝導率Approximately 193 W/(m·K) for the 3003 aluminum reheat fins at room temperature
表面仕上げNatural or coated aluminum fins with bright galvanized casing
ジョイントタイプBrazed copper tube/header joints inside a shallow flanged casing
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

One- or two-row circuitHeat-recovery, boiler-water or heat-pump-water serviceDifferent fin pitch and protective coatingsStainless casing with vent, drain and sensor pocket

Planning a Hot-Water Reheat Coil specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ