클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 HVAC 및 공기 처리 장비

온수 재열 코일

A shallow one- or two-row hydronic coil that restores neutral supply-air temperature after deep cooling and dehumidification.
  • Post-Dehumidification Reheat
  • Shallow Low-Pressure-Drop Face
  • Fast Valve Response
  • Compact AHU Integration
견적 요청 제품 찾아보기

상품 소개

The reheat coil is positioned downstream of a cooling coil so it can add sensible heat without increasing air moisture. Its shallow copper-tube and aluminum-fin construction minimizes air pressure drop while providing enough surface area for precise leaving-temperature control. Low water volume and short circuits respond quickly to a modulating valve, making the coil suitable for tight cleanroom temperature and humidity sequences.

주요 기능

One- or two-row construction limits fan energy while delivering controlled sensible reheat.

Small internal water volume responds rapidly when the modulating valve changes position.

Accessible vents and drains prevent air binding during low-flow operation.

Compact casing fits between cooling-coil, fan and final-filter sections in constrained AHUs.

고객 제품 관심사

Reheat must correct overcooled supply air precisely without adding excessive pressure drop or fighting the cooling sequence.

Air leaves the dehumidifying coil too cold for the occupied zone.A downstream hydronic coil adds only sensible heat and preserves the achieved moisture content.
An oversized multi-row coil causes sluggish temperature control.A shallow low-volume circuit responds quickly to modulating water flow.
Excessive fin resistance increases cleanroom fan power.A one- or two-row face and appropriate fin pitch minimize air-side pressure drop.
Simultaneous cooling and reheat waste plant energy.Heat-recovery or low-temperature return water can supply the reheat duty when available.

일반적인 응용 프로그램

Cleanroom temperature-humidity decouplingLaboratory dehumidification reheatHospital operating-room AHUsPharmaceutical make-up air unitsNeutral-temperature supply-air systems

기술 매개변수

Typical physical ranges for a compact AHU hot-water reheat coil are summarized below.

핵심 재료Copper tubes with aluminum fins and compact copper headers
패널 두께1.2-1.8 mm galvanized steel casing
유효 폭250-2200 mm active fin face width
최대 길이Up to 3200 mm overall casing length
강철 면면 두께1.2-1.8 mm galvanized or stainless frame
코어 밀도Approximately 2730 kg/m³ for the thin 3003 aluminum fin stock in the shallow reheat section
열전도도 (Thermal Conductivity)Approximately 193 W/(m·K) for the 3003 aluminum reheat fins at room temperature
표면 마무리Natural or coated aluminum fins with bright galvanized casing
접합 유형Brazed copper tube/header joints inside a shallow flanged casing
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

One- or two-row circuitHeat-recovery, boiler-water or heat-pump-water serviceDifferent fin pitch and protective coatingsStainless casing with vent, drain and sensor pocket

Planning a Hot-Water Reheat Coil specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기