Sistema de aire exterior dedicado
- Independent Latent Control
- Measured Ventilation Air
- Energy-Recovery Ready
- Stable Dry Supply Air
Introducción del producto
A dedicated outdoor air system separates ventilation and latent treatment from the high recirculation airflow used for cleanroom particle control. It receives 100% outdoor air, recovers useful energy from a separated exhaust stream where appropriate, cools and dries the air, then reheats it to a neutral or designed supply condition. This division lets terminal recirculation units handle sensible load and filtration without relying on them to remove the full outdoor-air moisture load. Airflow, dew point and supply temperature can be monitored independently.
Características clave
Deep dehumidification establishes a predictable supply dew point across seasonal outdoor conditions.
Plate, run-around or carefully selected rotary recovery can reduce outdoor-air heating and cooling load.
Reheat prevents overcooled ventilation air from causing local discomfort or excess sensible cooling.
Preocupaciones del producto del cliente
When ventilation air and recirculation air are treated together, moisture control can drift as outdoor conditions and room sensible loads change independently.
Aplicaciones típicas
Parámetros técnicos
Typical double-skin construction for a cleanroom dedicated outdoor air system is listed below.
| Materiales Core | Closed-cell polyurethane insulation in thermally separated double-skin panels |
|---|---|
| Panel de espesor | 50–70 mm insulated casing |
| Ancho efectivo | 1000–3400 mm nominal casing width |
| Longitud máxima | Up to 12000 mm including recovery, coil, reheat and fan modules |
| Acero frente a espesor | 0.6–1.0 mm outer skin and 0.8–1.0 mm wet-section lining |
| Densidad Core | 40–45 kg/m³ closed-cell polyurethane |
| Conductividad térmica | 0.022–0.026 W/(m·K) for the casing insulation |
| Superficie acabada | Powder-coated exterior with cleanable galvanized or stainless inner surfaces |
| Tipo conjunto | Compression-gasketed thermal-break panels with isolated supply and exhaust air paths |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Dedicated Outdoor Air System specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita